ASPEN模拟中 radfrac 模块质量不平衡以及干板的问题
aspen版本是7.2,做的是一个吸收CO2的循环流程,遇到的问题如下(已上传bkp文件到附件):Block: STRIPPER Model: RADFRAC* WARNING
FEED PRESSURE0.10132E+06 (N/SQM) OF STREAM F1
IS LOWER THAN STAGE 8 PRESSURE0.15231E+06 (N/SQM).
Convergence iterations:
OL ML IL Err/Tol
1 1 10 2957.1
2 1 10 6755.6
*** SEVERE ERROR
MATERIAL AND ENERGY BALANCES FAILED TO CONVERGE: CHECK COL-SPECS
OR SUPPLY BETTER TEMPERATURE AND COMPOSITION ESTIMATES.
*** SEVERE ERROR
THE FOLLOWING STAGES DRIED UP:
2 3 4 6
A LIMIT OF0.10000E-04 * SUM OF FEEDS WAS IMPOSED ON THE FLOW RATES.
**ERROR
BLOCK STRIPPER IS NOT IN MASS BALANCE:
MASS INLET FLOW = 0.27387925E+03, MASS OUTLET FLOW = 0.30153645E+03
RELATIVE DIFFERENCE = 0.10098318E+00
朋友,还记得当初是怎么解决的吗?我遇到了完全和你一样的问题,求指点一二,如果有资料,麻烦你发我一下,急用1287147184@qq.com
页:
[1]