hyjzx 发表于 2016-8-15 15:35:38

隔壁塔模拟求助

各位马友你们好!在隔壁塔模拟时出现这样的警告要怎么办呀!希望各位马友帮忙解决一下!谢谢了!warning in physical property system   equation of state model polysaft has missing parameters:   saftm (data set 1) missing for component 2m1b   an approximate value of3.3420assumed

longyanSA 发表于 2016-8-15 15:35:38

热力学方法不合适

hyjzx 发表于 2016-8-15 15:35:38

能不能再帮我看看这是哪里出错了?*** SEVERE ERROR
      A LIQUID FEED/PUMPAROUND TO THE TOP STAGE IS REQUIRED WHEN
      "Q1=0" IS SPECIFIED IN "COL-SPECS"; REQUIRED FEED/PUMPAROUND
      HAS ZERO FLOW.

*** SEVERE ERROR
      A VAPOR FEED/PUMPAROUND TO THE BOTTOM STAGE IS REQUIRED WHEN
      "QN=0" IS SPECIFIED IN "COL-SPECS"; REQUIRED FEED/PUMPAROUND
      HAS ZERO FLOW.

*   WARNING
      REST OF BLOCK BYPASSED DUE TO SEVERE ERROR.


谢谢了!

longyanSA 发表于 2016-8-15 15:35:38

泵回路的物流流量为零了
页: [1]
查看完整版本: 隔壁塔模拟求助