帮忙看看这个Fortran编的有问题吗?导入ASPEN之后运行不收敛,反应精馏塔中profile中的reaction显示都是0 C*********************************************************************** CLICENSED MATERIAL.PROPERTY OF ASPEN TECHNOLOGY, INC.TO BE * CTREATED AS ASPEN TECH PROPRIETARY INFORMATION UNDER THE TERMS * COF THE ASPEN PLUS SUBSCRIPTION AGREEMENT. * C*********************************************************************** C----------------------------------------------------------------------- C COPYRIGHT (C) 1994 C ASPEN TECHNOLOGY, INC. C CAMBRIDGE, MA C----------------------------------------------------------------------- C C calculation of MTBE synthesis reaction rate C User Kinetics Subroutine for RADFRAC, BATCHFRAC, RATEFRAC C SUBROUTINE DIB (NSTAGE, NCOMP, NR, NRL, NRV, 2 T, TLIQ, TVAP, P, VF, 3 F, X, Y, IDX, NBOPST, 4 KDIAG,STOIC, IHLBAS, HLDLIQ,TIMLIQ, 5 IHVBAS, HLDVAP,TIMVAP, NINT, INT, 6 NREAL,REAL, RATES,RATEL, RATEV, 7 NINTB,INTB, NREALB, REALB, NIWORK, 8 IWORK,NWORK, WORK) C C VARIABLES IN ARGUMENT LIST C C VARIABLEI/OTYPE DIMENSION DESCRIPTION AND RANGE C NSTAGE I I - STAGE NUMBER C NCOMP I I - NUMBER OF COMPONENTS C NR I I - TOTAL NUMBER OF KINETIC C REACTIONS C NRL I I - NUMBER OF LIQUID PHASE C KINETIC REACTIONS C NRV I I - NUMBER OF VAPOR PHASE C KINETIC REACTIONS C T I R - STAGE TEMPERATURE (K) C TLIQ I R - LIQUID TEMPERATURE (K) C * USED ONLY BY RATEFRAC ** C TVAP I R - VAPOR TEMPERATURE (K) C * USED ONLY BY RATEFRAC ** C P I R - STAGE PRESSURE (N/SQ.M) C VF I R - VAPOR FRACTION C F I R - TOTAL FLOW ON STAGE C (VAPOR+LIQUID) (KMOL/SEC) C X I R NCOMP,3 LIQUID MOLE FRACTION C Y I R NCOMP VAPOR MOLE FRACTION C IDX I I NCOMP COMPONENT INDEX VECTOR C NBOPST I I 6 OPTION SET BEAD POINTER C KDIAG I I - LOCAL DIAGNOSTIC LEVEL C STOIC I R NCOMP,NR REACTION STOICHIOMETRY C IHLBAS I I - BASIS FOR LIQUID C HOLDUP SPECIFICATION C 1:VOLUME,2:MASS,3:MOLE C HLDLIQ I R - LIQUID HOLDUP C IHLBAS UNITS C 1 CU.M. C 2 KG C 3 KMOL C TIMLIQ I R - LIQUID RESIDENCE TIME C (SEC) C IHVBAS I I - BASIS FOR VAPOR C HOLDUP SPECIFICATION C 1:VOLUME,2:MASS,3:MOLE C HLDVAP I R - VAPOR HOLDUP C IHVBAS UNITS C 1 CU.M. C 2 KG C 3 KMOL C TIMVAP I R - VAPOR RESIDENCE TIME (SEC) C NINT I I - LENGTH OF INTEGER VECTOR C INT I/O I NINT INTEGER VECTOR C NREAL I I - LENGTH OF REAL VECTOR C REAL I/O R NREAL REAL VECTOR C RATES O R NCOMP COMPONENT REACTION RATES C (KMOL/SEC) C RATEL O R NRL INDIVIDUAL REACTION RATES C IN THE LIQUID PHASE C (KMOL/SEC) C * USED ONLY BY RATEFRAC ** C RATEV O R NRV INDIVIDUAL REACTION RATES C IN THE VAPOR PHASE C (KMOL/SEC) C * USED ONLY BY RATEFRAC ** C NINTB I I - LENGTH OF INTEGER VECTOR C (FROM UOS BLOCK) C INTB I/O I NINTB INTEGER VECTOR C (FROM UOS BLOCK) C NREALB I I - LENGTH OF REAL VECTOR C (FROM UOS BLOCK) C REALB I/O R NREALB REAL VECTOR C (FROM UOS BLOCK) C NIWORK I I - LENGTH OF INTEGER WORK C VECTOR C IWORK I/O I NIWORK INTEGER WORK VECTOR C NWORK I I - LENGTH OF REAL WORK VECTOR C WORK I/O R NWORK REAL WORK VECTOR C C*********************************************************************** C IMPLICIT NONE C C DECLARE VARIABLES USED IN DIMENSIONING C INTEGER NCOMP, NR, NRL, NRV, NINT, + NINTB, NREALB,NIWORK,NWORK, N_COMP C C DECLARE PARAMETERS & VARIABLES USED IN PARAMETERS C INTEGER K_IB,K_DIB, K_TI, K_IP, K_TBA PARAMETER(K_IB=1) PARAMETER(K_DIB=2) PARAMETER(K_TI=3) PARAMETER(K_IP=4) PARAMETER(K_TBA=5) PARAMETER(N_COMP=5)C component order C =============== C this routine assumes that the components are in this order : C C DECLARE ARGUMENTS C INTEGER IDX(NCOMP), NBOPST(6), INT(NINT), + INTB(NINTB),IWORK(NIWORK),NSTAGE, + KDIAG, IHLBAS,IHVBAS,NREAL, KPHI, + KER, L_GAMMA, J REAL*8 X(NCOMP,3), Y(NCOMP), + STOIC(NCOMP,NR), RATES(NCOMP), + RATEL(NRL), RATEV(NRV), + REALB(NREALB),WORK(NWORK),B(1),T, + TLIQ,TVAP,P, VF, F REAL*8 HLDLIQ,TIMLIQ,HLDVAP,TIMVAP C C C DECLARE SYSTEM FUNCTIONS C REAL*8 DLOG C C DECLARE LOCAL VARIABLES C INTEGER IMISS, IDBG REAL*8 REAL(NREAL),RMISS,DKR(2), + RATE(2),RATNET(2),KA,KB REAL*8 PHI(N_COMP) REAL*8 DPHI(N_COMP) REAL*8 ACTIV(N_COMP)C #include "ppexec_user.cmn" EQUIVALENCE (RMISS, USER_RUMISS) EQUIVALENCE (IMISS, USER_IUMISS) C C #include "dms_maxwrt.cmn" #include "dms_ipoff3.cmn" #include "dms_lclist.cmn" INTEGER FN#include "dms_plex.cmn" EQUIVALENCE(B(1),IB(1)) FN(J)=J+LCLIST_LBLCLIST C C DATA STATEMENTS C DATA IDBG/0/C thermodynamic rate constant DKA C =============================== 9010 FORMAT(1X,3(G13.6,1X)) 9000 FORMAT(' fugly failed at T=',G12.5,' P=',G12.5,' ker=',I4) 9020 FORMAT(' compo ',I3,' mole-frac=',G12.5,' activity=',G12.5) 9030 FORMAT(' stage=',I4,' spec-rate=',G12.5,' net-rate=',G12.5) C C BEGIN EXECUTABLE CODE C DKR(1)=(2.278D+10*DEXP(-30000.D+00/8.314/T)) DKR(2)=(1.81D+9*DEXP(-1800.D+00/8.314/T)) KA=7.D+00 KB=1.2D-01 IF(IDBG.GE.1)THEN WRITE(MAXWRT_MAXBUF(1),9010) DKR(1),DKR(2),KA,KB CALL DMS_WRTTRM(1) ENDIFC calculation of components activities C ==================================== C calculate only fugacity coefficient KPHI=1C fugacity coefficient of components in the mixture CALL PPMON_FUGLY(T,P,X(1,1) + ,Y,NCOMP,IDX,NBOPST,KDIAG,KPHI,PHI,DPHI,KER) IF(KER.NE.0)THEN WRITE(MAXWRT_MAXBUF(1),9000) T,P,KER CALL DMS_WRTTRM(1) ENDIFC set offset to get activity coefficients C (see vol5, p 11-11 and asp$sor search for 'GAMMAL') L_GAMMA=IPOFF3_IPOFF3(24)C calculate activities for plex data DO J=1,NCOMP ACTIV(J)=DEXP(B(FN(L_GAMMA)+J))*X(J,1) END DO IF(IDBG.GE.1)THEN DO J=1,NCOMP WRITE(MAXWRT_MAXBUF(1),9020) J,X(J,1),ACTIV(J) CALL DMS_WRTTRM(1) END DO ENDIF C use mass holdup as kgcata CSCRATCH THAT...THATS WITH VERSION 9, IN 10 USE REALB(1) AS TOTAL MASS. IF (ACTIV(K_IB) .GT. 0.D0) THEN RATE(1)=(DKR(1)*(ACTIV(K_IB))**2.d0/(ACTIV(K_IB)+KA*ACTIV(K_TBA) *+KB*ACTIV(K_IP))**2.d0) RATE(2)=(DKR(2)*ACTIV(K_IB)*ACTIV(K_DIB)/(ACTIV(K_IB)+KA **ACTIV(K_TBA)+KB*ACTIV(K_IP))**3.d0) ELSE RATE(1) = 0.D+00 RATE(2) = 0.D+00 END IF RATNET(1)=RATE(1)*REALB(1)*1.D-03 RATNET(2)=RATE(2)*REALB(1)*1.D-03 RATES(K_IB)=-RATNET(1)-RATNET(1)-RATNET(2) RATES(K_DIB)=RATNET(1)-RATNET(2) RATES(K_TI)=RATNET(2) RATES(K_TBA)=0.D+00 RATES(K_IP)=0.D+00 IF(IDBG.GE.1)THEN WRITE(MAXWRT_MAXBUF(1),9030) NSTAGE,RATE(1),RATE(2),RATNET(1), + RATNET(2) CALL DMS_WRTTRM(1) ENDIF RETURN #undef P_MAX3 END- 本文出自马后炮化工-让天下没有难学的化工技术,原文地址:https://meng.horse/thread-214404-1-1.html 楼主,这是我编写的一个动力学方程,能成功嵌入到ASPEN中,不过运行后发现反应精馏塔的反应段reaction全为0.是不是我动力学方程编写的出了问题,请楼主帮忙看看
C***********************************************************************
CLICENSED MATERIAL.PROPERTY OF ASPEN TECHNOLOGY, INC.TO BE *
CTREATED AS ASPEN TECH PROPRIETARY INFORMATION UNDER THE TERMS *
COF THE ASPEN PLUS SUBSCRIPTION AGREEMENT. *
C***********************************************************************
C-----------------------------------------------------------------------
C COPYRIGHT (C) 1994
C ASPEN TECHNOLOGY, INC.
C CAMBRIDGE, MA
C-----------------------------------------------------------------------
C
C calculation of MTBE synthesis reaction rate
C User Kinetics Subroutine for RADFRAC, BATCHFRAC, RATEFRAC
C
SUBROUTINE DIB (NSTAGE, NCOMP, NR, NRL, NRV,
2 T, TLIQ, TVAP, P, VF,
3 F, X, Y, IDX, NBOPST,
4 KDIAG,STOIC, IHLBAS, HLDLIQ,TIMLIQ,
5 IHVBAS, HLDVAP,TIMVAP, NINT, INT,
6 NREAL,REAL, RATES,RATEL, RATEV,
7 NINTB,INTB, NREALB, REALB, NIWORK,
8 IWORK,NWORK, WORK)
C
C VARIABLES IN ARGUMENT LIST
C
C VARIABLEI/OTYPE DIMENSION DESCRIPTION AND RANGE
C NSTAGE I I - STAGE NUMBER
C NCOMP I I - NUMBER OF COMPONENTS
C NR I I - TOTAL NUMBER OF KINETIC
C REACTIONS
C NRL I I - NUMBER OF LIQUID PHASE
C KINETIC REACTIONS
C NRV I I - NUMBER OF VAPOR PHASE
C KINETIC REACTIONS
C T I R - STAGE TEMPERATURE (K)
C TLIQ I R - LIQUID TEMPERATURE (K)
C * USED ONLY BY RATEFRAC **
C TVAP I R - VAPOR TEMPERATURE (K)
C * USED ONLY BY RATEFRAC **
C P I R - STAGE PRESSURE (N/SQ.M)
C VF I R - VAPOR FRACTION
C F I R - TOTAL FLOW ON STAGE
C (VAPOR+LIQUID) (KMOL/SEC)
C X I R NCOMP,3 LIQUID MOLE FRACTION
C Y I R NCOMP VAPOR MOLE FRACTION
C IDX I I NCOMP COMPONENT INDEX VECTOR
C NBOPST I I 6 OPTION SET BEAD POINTER
C KDIAG I I - LOCAL DIAGNOSTIC LEVEL
C STOIC I R NCOMP,NR REACTION STOICHIOMETRY
C IHLBAS I I - BASIS FOR LIQUID
C HOLDUP SPECIFICATION
C 1:VOLUME,2:MASS,3:MOLE
C HLDLIQ I R - LIQUID HOLDUP
C IHLBAS UNITS
C 1 CU.M.
C 2 KG
C 3 KMOL
C TIMLIQ I R - LIQUID RESIDENCE TIME
C (SEC)
C IHVBAS I I - BASIS FOR VAPOR
C HOLDUP SPECIFICATION
C 1:VOLUME,2:MASS,3:MOLE
C HLDVAP I R - VAPOR HOLDUP
C IHVBAS UNITS
C 1 CU.M.
C 2 KG
C 3 KMOL
C TIMVAP I R - VAPOR RESIDENCE TIME (SEC)
C NINT I I - LENGTH OF INTEGER VECTOR
C INT I/O I NINT INTEGER VECTOR
C NREAL I I - LENGTH OF REAL VECTOR
C REAL I/O R NREAL REAL VECTOR
C RATES O R NCOMP COMPONENT REACTION RATES
C (KMOL/SEC)
C RATEL O R NRL INDIVIDUAL REACTION RATES
C IN THE LIQUID PHASE
C (KMOL/SEC)
C * USED ONLY BY RATEFRAC **
C RATEV O R NRV INDIVIDUAL REACTION RATES
C IN THE VAPOR PHASE
C (KMOL/SEC)
C * USED ONLY BY RATEFRAC **
C NINTB I I - LENGTH OF INTEGER VECTOR
C (FROM UOS BLOCK)
C INTB I/O I NINTB INTEGER VECTOR
C (FROM UOS BLOCK)
C NREALB I I - LENGTH OF REAL VECTOR
C (FROM UOS BLOCK)
C REALB I/O R NREALB REAL VECTOR
C (FROM UOS BLOCK)
C NIWORK I I - LENGTH OF INTEGER WORK
C VECTOR
C IWORK I/O I NIWORK INTEGER WORK VECTOR
C NWORK I I - LENGTH OF REAL WORK VECTOR
C WORK I/O R NWORK REAL WORK VECTOR
C
C***********************************************************************
C
IMPLICIT NONE
C
C DECLARE VARIABLES USED IN DIMENSIONING
C
INTEGER NCOMP, NR, NRL, NRV, NINT,
+ NINTB, NREALB,NIWORK,NWORK, N_COMP
C
C DECLARE PARAMETERS & VARIABLES USED IN PARAMETERS
C
INTEGER K_IB,K_DIB, K_TI, K_IP, K_TBA
PARAMETER(K_IB=1)
PARAMETER(K_DIB=2)
PARAMETER(K_TI=3)
PARAMETER(K_IP=4)
PARAMETER(K_TBA=5)
PARAMETER(N_COMP=5)
C component order
C ===============
C this routine assumes that the components are in this order :
C
C DECLARE ARGUMENTS
C
INTEGER IDX(NCOMP), NBOPST(6), INT(NINT),
+ INTB(NINTB),IWORK(NIWORK),NSTAGE,
+ KDIAG, IHLBAS,IHVBAS,NREAL, KPHI,
+ KER, L_GAMMA, J
REAL*8 X(NCOMP,3), Y(NCOMP),
+ STOIC(NCOMP,NR), RATES(NCOMP),
+ RATEL(NRL), RATEV(NRV),
+ REALB(NREALB),WORK(NWORK),B(1),T,
+ TLIQ,TVAP,P, VF, F
REAL*8 HLDLIQ,TIMLIQ,HLDVAP,TIMVAP
C
C
C DECLARE SYSTEM FUNCTIONS
C
REAL*8 DLOG
C
C DECLARE LOCAL VARIABLES
C
INTEGER IMISS, IDBG
REAL*8 REAL(NREAL),RMISS,DKR(2),
+ RATE(2),RATNET(2),KA,KB
REAL*8 PHI(N_COMP)
REAL*8 DPHI(N_COMP)
REAL*8 ACTIV(N_COMP)
C
#include "ppexec_user.cmn"
EQUIVALENCE (RMISS, USER_RUMISS)
EQUIVALENCE (IMISS, USER_IUMISS)
C
C
#include "dms_maxwrt.cmn"
#include "dms_ipoff3.cmn"
#include "dms_lclist.cmn"
INTEGER FN
#include "dms_plex.cmn"
EQUIVALENCE(B(1),IB(1))
FN(J)=J+LCLIST_LBLCLIST
C
C DATA STATEMENTS
C
DATA IDBG/0/
C thermodynamic rate constant DKA
C ===============================
9010 FORMAT(1X,3(G13.6,1X))
9000 FORMAT(' fugly failed at T=',G12.5,' P=',G12.5,' ker=',I4)
9020 FORMAT(' compo ',I3,' mole-frac=',G12.5,' activity=',G12.5)
9030 FORMAT(' stage=',I4,' spec-rate=',G12.5,' net-rate=',G12.5)
C
C BEGIN EXECUTABLE CODE
C
DKR(1)=(2.278D+10*DEXP(-30000.D+00/8.314/T))
DKR(2)=(1.81D+9*DEXP(-1800.D+00/8.314/T))
KA=7.D+00
KB=1.2D-01
IF(IDBG.GE.1)THEN
WRITE(MAXWRT_MAXBUF(1),9010) DKR(1),DKR(2),KA,KB
CALL DMS_WRTTRM(1)
ENDIF
C calculation of components activities
C ====================================
C calculate only fugacity coefficient
KPHI=1
C fugacity coefficient of components in the mixture
CALL PPMON_FUGLY(T,P,X(1,1)
+ ,Y,NCOMP,IDX,NBOPST,KDIAG,KPHI,PHI,DPHI,KER)
IF(KER.NE.0)THEN
WRITE(MAXWRT_MAXBUF(1),9000) T,P,KER
CALL DMS_WRTTRM(1)
ENDIF
C set offset to get activity coefficients
C (see vol5, p 11-11 and asp$sor search for 'GAMMAL')
L_GAMMA=IPOFF3_IPOFF3(24)
C calculate activities for plex data
DO J=1,NCOMP
ACTIV(J)=DEXP(B(FN(L_GAMMA)+J))*X(J,1)
END DO
IF(IDBG.GE.1)THEN
DO J=1,NCOMP
WRITE(MAXWRT_MAXBUF(1),9020) J,X(J,1),ACTIV(J)
CALL DMS_WRTTRM(1)
END DO
ENDIF
C use mass holdup as kgcata
CSCRATCH THAT...THATS WITH VERSION 9, IN 10 USE REALB(1) AS TOTAL MASS.
IF (ACTIV(K_IB) .GT. 0.D0) THEN
RATE(1)=(DKR(1)*(ACTIV(K_IB))**2.d0/(ACTIV(K_IB)+KA*ACTIV(K_TBA)
*+KB*ACTIV(K_IP))**2.d0)
RATE(2)=(DKR(2)*ACTIV(K_IB)*ACTIV(K_DIB)/(ACTIV(K_IB)+KA
**ACTIV(K_TBA)+KB*ACTIV(K_IP))**3.d0)
ELSE
RATE(1) = 0.D+00
RATE(2) = 0.D+00
END IF
RATNET(1)=RATE(1)*REALB(1)*1.D-03
RATNET(2)=RATE(2)*REALB(1)*1.D-03
RATES(K_IB)=-RATNET(1)-RATNET(1)-RATNET(2)
RATES(K_DIB)=RATNET(1)-RATNET(2)
RATES(K_TI)=RATNET(2)
RATES(K_TBA)=0.D+00
RATES(K_IP)=0.D+00
IF(IDBG.GE.1)THEN
WRITE(MAXWRT_MAXBUF(1),9030) NSTAGE,RATE(1),RATE(2),RATNET(1),
+ RATNET(2)
CALL DMS_WRTTRM(1)
ENDIF
RETURN
#undef P_MAX3
END
- 本文出自马后炮化工-让天下没有难学的化工技术,原文地址:https://meng.horse/thread-214404-1-1.html 本帖最后由 bshao_sh 于 2018-6-14 16:47 编辑
波波 发表于 2018-6-14 15:06
请教
aspen自带的SOLID1例子是关于煤干燥的例子。
其中用到calculator,用fortran语言。
[*]H2OIN定义为stream WET-COAL中 NC-Substream 里 mositure(水)含量。
[*]CONV是煤到水的转化率。因为煤是一个含水的混合物,干燥过程是添加一个反应让煤反应生成水来处理。Plus 里NC 分子量默认为1, 所以水反应系数是1/18=0.0555084。
[*]H2ODry是反应器内NC-Substream 中 mositure(水)含量。
[*]H2ODRY = 10.0 指定出口含水量
[*]CONV = (H2OIN - H2ODRY) / (100 - H2ODRY) 计算达到指定出口含水量时coal转化率。
[*]公式推导
以100mol coal进料为例: 反应前水量=生成水量 + 剩余水量 100*H2OIN /100 = 100*CONV+100*(1-CONV)*H2ODry/100 H2OIN = 100*CONV+(1-CONV)*H2ODry *** SEVERE ERROR COULD NOT RESOLVE USER OR IN-LINE FORTRAN SUBROUTINE(S): SUBROUTINE "USRKNT" IS MISSING *** SEVERE ERROR PROGRAM TERMINATED DUE TO UNRESOLVED ROUTINES 动力学方程用fortran6.6编写,引入aspen时没报错,一运行aspen就出上面的错误 - 楼主你好,V8.4版本,编译器组合是IVF12+VS2008
可以编译生成OBJ文件,但是生成DLL这一步的ASPLINK命令无法执行
从网上找的文件,链接DLL文件时可以执行,但是链接OBJ文件的时候就出错
怀疑是编译器没安装好,但是SetCompiler那里又显示OK,这是怎么回事?求楼主解惑。 xsahh 发表于 2017-1-5 21:50
楼主,对于反应精馏,考虑催化剂内外扩散阻力的条件下进行计算。怎么通过Fortan语言获得传质方程最基本的参 ...
user defined subroutines 只能算气液相间传递,你说的内外扩散无解。
我不知道St是什么,浓度梯度应该是解微分方程算出来的,内扩散就是个PDE方程,扩散系数由一堆经验关联式计算。 楼主您好,我的电脑上装了Aspen Plus V8.4、Visual Studio 2012和Intel Parallel Studio XE 2013,可以正常编译程序和调试。但是,在链接的时候出现了问题,首先是在Set Compiler for V8.4窗口未出现可用的编译器组合。其次,在调用子程序的时候。未找到可用的子程序,(错误可以参考截图),请问是什么原因导致的?多谢回答,多谢 黄盖 发表于 2017-1-4 08:40
请问楼主有没有aspen fortran方面入门的教程之类的,还是说直接学习fortran语言就行了
入门的话建议先简单看下F77的基本语法,懂得判断循环就差不多了。然后对照
C:\Program Files (x86)\AspenTech\Aspen Plus VX.X\Engine\User下给的模版和Aspen Plus User Models.pdf看就可以了。 用engine编译obj的时候,报错,出现No compiler set is selected for use with this version of AspenPlus. You need to run correct "Set Compiler for Vxx" and select a supported C++ and Fortran compiler set that have been installed on your system. bshao_sh 发表于 2018-1-22 20:14
大概你得去找找AOS相关的东西,难度比较大。
建议用过c#或者vb.net 连接aspen, 然后实现相应的优化算法 ...
您好,我导师建议我先将aspen与fortran链接起来,但现在还不知道怎么做,您有什么经验或者教程之类的吗? y--h--- 发表于 2018-5-6 09:55
*** SEVERE ERROR COULD NOT RESOLVE USER OR IN-LINE FORTRAN SUBROUTINE(S): SUBROUTINE "U ...
找不到subroutone,help里搜dlopt。 2583084747 发表于 2018-5-8 19:34
您好,我想问一下Aspen plus用Fortran编写程序实现液体膜分离怎么做,比如我是想分离甲醇,实现富集
自己加一个user model,可以用fortran或者ACM。先查下怎么做,剩下的就是把你的当成套进去了。 huweijilian 发表于 2017-1-8 13:04
Fortranv6在aspenv9和win7下没法设置,全是erorr。但aspenv7时可行。必须加装Visual-Studio-2010吗?
按description对应匹配的Fortran和VS版本安装。V9.0貌似只支持F9.X之后版本了。 huweijilian 发表于 2017-1-8 13:04
Fortranv6在aspenv9和win7下没法设置,全是erorr。但aspenv7时可行。必须加装Visual-Studio-2010吗?
按description对应匹配的Fortran和VS版本安装。V9.0貌似只支持F9.X之后版本了。 bshao_sh 发表于 2018-6-14 16:45
[*]H2OIN定义为stream WET-COAL中 NC-Substream 里 mositure(水)含量。
[*]CONV是煤到水的转化率。因为 ...
谢谢
那么第二行中,ID1=1是什么含义?
第三行中,ID1=NCPSD,ID2=COAL,ID3=PROXANAL是什么含义
再次感谢 xsahh 发表于 2018-4-8 22:07
咨询一个问题:ASPEN中IDX代表什么意思?能不能举一个例子或简单的代码说明下,查了help文件,没有太明白
IDX是组分的数组,值表示在components/specification 里的位置,纬度是组分个数。 ZL琳 发表于 2019-5-20 09:11
楼主您好,我的电脑上装了Aspen Plus V8.4、Visual Studio 2012和Intel Parallel Studio XE 2013,可以正常 ...
Visual Studio 2010 和 Intel Parallel Studio XE2011是标配,基本上Aspen7.3-10都能链接 大神你好,我用fortran自定义了一个模块,模拟的系统中有两个部件都由该模型模拟,但是嵌入后,只能实现一个正确模拟,另一个得到的结果是自己的结果与第一个模块模拟结果的和,大神您有比较好的建议吗?谢谢您 大神你好,我用fortran自定义了一个模块,模拟的系统中有两个部件都由该模型模拟,但是嵌入后,只能实现一个正确模拟,另一个得到的结果是自己的结果与第一个模块模拟结果的和,大神您有比较好的建议吗?谢谢您 波波 发表于 2018-6-19 08:53
谢谢
那么第二行中,ID1=1是什么含义?
1. ID1=1 表示第一个反应。
2. ID1 是solid sustream, ID2是solid component, ID3是组成分析,ID4表示第一个值即mositure含量。
仔细看,tooltip是有写的。 1354071132 发表于 2018-1-22 18:56
楼主你好,请问fortran如何和aspen关联起来做优化
大概你得去找找AOS相关的东西,难度比较大。
建议用过c#或者vb.net 连接aspen, 然后实现相应的优化算法会简单一点。
想问您一下 我有一个费托合成的反应精馏塔 体系在规定物性的时候methods选用PRMHV2, 但是计算liquid phase activity coefficient想用UNIFAC计算 请问怎么设置 需要用到fortran吗?
附件是我的apwz C:\Program Files (x86)\AspenTech\reaction>aspcomp CSTR.F
拒绝访问。
拒绝访问。
拒绝访问。
Error in compiling preprocessed file: Check compile.log
请问这个是什么原因呢 设计规定中manipulate的变量是通过一系列fortran语句表达的,但是运行结束,发现fortran中的中间变量都没有被计算,这些变量是流程中的属于自己定义parameter变量,想问下怎么解决 一柱张 发表于 2017-1-12 07:31
想问您一下 我有一个费托合成的反应精馏塔 体系在规定物性的时候methods选用PRMHV2, 但是计算liquid phase ...
不用这么费劲,更改液相活度计算方程就可以 bshao_sh 发表于 2018-5-12 10:15
有两个选择,用user2 model或者写 ACM model。自己去找例子吧。
你好,不知道您有没有时间,可以教我做一个ASPEN流程模拟吗,需要加入一些模型,有偿帮忙 g12121212f 发表于 2022-6-16 22:08
用engine编译obj的时候,报错,出现No compiler set is selected for use with this version of AspenPlu ...
这是什么情况,没有装C++吗?
ZL琳 发表于 2019-5-20 09:11
楼主您好,我的电脑上装了Aspen Plus V8.4、Visual Studio 2012和Intel Parallel Studio XE 2013,可以正常 ...
请问这个问题你解决了嘛?我遇到相同问题 静水流深3456 发表于 2017-2-17 20:54
大神你好,我用fortran自定义了一个模块,模拟的系统中有两个部件都由该模型模拟,但是嵌入后,只能实现一 ...
方便的话把文件发我看看。 李田所 发表于 2018-1-8 20:44
楼主你好,V8.4版本,编译器组合是IVF12+VS2008
可以编译生成OBJ文件,但是生成DLL这一步的ASPLINK命令 ...
编译dll改成 asplink usrkin.dll bshao_sh 发表于 2018-1-22 20:17
发个文件看看。
希望通过改变fsplit的分离率来研究其对物流3、4的温度影响,但是建立灵敏度分析后运行之后这两个参数不变 晓伙子QT 发表于 2018-1-5 21:10
设计规定中manipulate的变量是通过一系列fortran语句表达的,但是运行结束,发现fortran中的中间变量都没有 ...
发个文件看看。 zsyall 发表于 2017-5-23 09:16
楼主你好,如果aspen中没有的模块,选user1,用Fortran来做,然后编一个程序,让流股中其中一种物料被吸收 ...
这个用calculator不行么??? 一柱张 发表于 2017-1-12 07:31
想问您一下 我有一个费托合成的反应精馏塔 体系在规定物性的时候methods选用PRMHV2, 但是计算liquid phase ...
参考10楼的方法。 czhllt 发表于 2019-7-15 11:21
Visual Studio 2010 和 Intel Parallel Studio XE2011是标配,基本上Aspen7.3-10都能链接
是的,我已经安装上了,运行很顺利,谢谢。 Mia__ 发表于 2018-5-11 08:43
大神,我想做吸收模拟分离二元混合气,想用自己做的吸收模型(压力和溶解度关联模型),请问可以实现吗
当然可以。 楼主,对于反应精馏,考虑催化剂内外扩散阻力的条件下进行计算。怎么通过Fortan语言获得传质方程最基本的参数:如St,浓度梯度等用于求解扩散方程? 请问能不能讲一下user模块软件的界面怎么设置?就是number of parameter,length of work arrays,和values for parameters都应该怎么填,谢谢! Mia__ 发表于 2018-5-29 10:17
你好,不知道您有没有时间,可以教我做一个ASPEN流程模拟吗,需要加入一些模型,有偿帮忙
加我好友先。 楼主你好,动力学方程多了一个机理函数,和转化率有关,如附件所示,应该怎样用Fortran编程或者怎样在aspen中设置一些参数?万分感谢 19811211 发表于 2019-11-13 11:14
请问这个问题你解决了嘛?我遇到相同问题
我现在装的是VS2010和IVF2013,可以适用于Aspen Plus V8.4 bshao_sh 发表于 2018-6-20 17:58
1. ID1=1 表示第一个反应。
2. ID1 是solid sustream, ID2是solid component, ID3是组成分析,ID4表示第 ...
谢谢! 楼主你好,如果aspen中没有的模块,选user1,用Fortran来做,然后编一个程序,让流股中其中一种物料被吸收,其他组成不变,这样能做到吗? Mia__ 发表于 2018-5-11 16:09
求简单指导方向,我慢慢学~万分感谢
有两个选择,用user2 model或者写 ACM model。自己去找例子吧。 大仁仁 发表于 2017-5-18 22:06
楼主大大你好,我想模拟干燥器,但是运行时候弹出来FORTRAN OVERFLOW ENCOUNTERED.
麻烦附上文件。 bshao_sh 发表于 2017-1-8 22:02
按description对应匹配的Fortran和VS版本安装。V9.0貌似只支持F9.X之后版本了。
谢谢,学习 啦 本帖最后由 huweijilian 于 2017-1-8 13:08 编辑
Fortranv6在aspenv9和win7下没法设置,全是erorr。但aspenv7时可行。必须加装Visual-Studio-2010吗? 楼主 您好 我的 Aspen V10 后面装了 VS2015和IVF2017 显示OK了 但是在Aspen里面还是显示缺少合适的编译器 求指导 咨询一个问题:ASPEN中IDX代表什么意思?能不能举一个例子或简单的代码说明下,查了help文件,没有太明白 一柱张 发表于 2017-1-13 02:26
但是貌似这样不能定义亨利组分啊,求指教!
你自己在研究下吧,这块不是很了解。 请问楼主有没有aspen fortran方面入门的教程之类的,还是说直接学习fortran语言就行了 编程,感觉很高深啊!{:1106_363:} {:1106_362:}………………………… 本帖最后由 一柱张 于 2017-1-13 02:27 编辑
bshao_sh 发表于 2017-1-12 20:08
参考10楼的方法。
但是貌似这样不能定义亨利组分啊,求指教! {:1106_382:}