请教大家个问题。HTRI报告显示No thermosiphom instability threshold could be found within thespecified operating range of the heat exchanger. Because of the low weightfraction vapor at the exchanger exit, HTRI data suggests that the systemstability is probable.我这个是由于气化率太低导致。我想知道在实际操作中再沸器能否实现循环呢?还是真如报告所说无法实现如果你用的是正版软件,可以直接请教HTRI技术支持:support@htri.net;如果写英文有困难,就发给HTRI中国代表:htri.china@htri.net,他们一定会帮助的。