《求助!》旋风分离器入口压力和流速过大怎么弄
<< Run reinitialized 20:34:12 Wed Mar 15, 2017>>->Processing input specifications ...
Flowsheet Analysis :
COMPUTATION ORDER FOR THE FLOWSHEET:
HUNHE FENLIQI
->Calculations begin ...
Block: HUNHE Model: MIXER
Block: FENLIQIModel: CYCLONE
* WARNING
INLET VELOCITY IS HIGHER THAN CORRELATION LIMITATION 30 M/S
INLET GAS VELOCITY IS (0.269E+04) .
INFORMATION
RATIO OF INLET TO SALTATION VELOCITY 5.88 IS GREATER THAN 1.36,
SOLIDS REENTRAINMENT MAY OCCUR.
* WARNING
PRESSURE DROP (0.20331E+08) IS ABOVE MAXIMUM
PRESSURE DROP SET TO MAXIMUM 85050. N/SQM .
->Simulation calculations completed ...
***No Warnings were issued during Input Translation ***
***Summary of Simulation Errors***
Physical
Property System Simulation
Terminal Errors 0 0 0
Severe Errors 0 0 0
Errors 0 0 0
Warnings 0 0 2{:1106_399:}
本帖最后由 imeagor 于 2017-3-16 09:46 编辑
旋风分离器的进口速度不能太小,否则颗粒会在进口管内沉积;也不能太大,否则颗粒无法在旋风分离器内沉降下来
这其中涉及一个颗粒不沉积的气流速度,就是saltation 速度。实验研究表明,入口气流速度不能超过saltation速度的1.36倍。
你的模拟案例中可能入口气速太大了,达到了saltation速度的5.88倍,压降当然也大大超过了最大的压降
建议你增加旋风分离器的尺寸,降低进口气速
imeagor 发表于 2017-3-16 09:11
旋风分离器的进口速度不能太小,否则颗粒会在进口管内沉积;也不能太大,否则颗粒无法在旋风分离器内沉降下 ...
恩恩我该用什么降低气速啊 ?用物流倍增器还是汽轮机什么的呀?{:1106_400:} 冬二君 发表于 2017-3-16 18:20
恩恩我该用什么降低气速啊 ?用物流倍增器还是汽轮机什么的呀?
增加旋风分离器的尺寸,也就是增加进口的尺寸,这样在一定的流量的情况下,流速就会降下来 楼主问题解决了吗请教
{:1106_362:} 你好楼主 你的旋风分离模拟选用的是什么模块啊?
页:
[1]