迦南0518 发表于 2017-5-17 22:32:44

想问一下出现这种warning的原因是什么?? 一个没有锅炉的简单二级克劳斯转化。含b...

想问一下出现这种warning的原因是什么??
一个没有锅炉的简单二级克劳斯转化。含bkp文件
谢谢!!



Run reinitialized 22:24:11 Wed May 17, 2017>>



->Processing input specifications ...

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      EQUATION OF STATE MODEL POLYSL HAS MISSING PARAMETERS:
      SLPSTR (DATA SET 1) MISSING FOR COMPONENT CO
      A NOMINAL VALUE OF3000. (bar) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLTSTR (DATA SET 1) MISSING FOR COMPONENT CO
      A NOMINAL VALUE OF415. (K) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLRSTR (DATA SET 1) MISSING FOR COMPONENT CO
      A NOMINAL VALUE OF736. (KG/CUM) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLPSTR (DATA SET 1) MISSING FOR COMPONENT H2
      A NOMINAL VALUE OF3000. (bar) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLTSTR (DATA SET 1) MISSING FOR COMPONENT H2
      A NOMINAL VALUE OF415. (K) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLRSTR (DATA SET 1) MISSING FOR COMPONENT H2
      A NOMINAL VALUE OF736. (KG/CUM) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLPSTR (DATA SET 1) MISSING FOR COMPONENT CO2
      A NOMINAL VALUE OF3000. (bar) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLTSTR (DATA SET 1) MISSING FOR COMPONENT CO2
      A NOMINAL VALUE OF415. (K) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLRSTR (DATA SET 1) MISSING FOR COMPONENT CO2
      A NOMINAL VALUE OF736. (KG/CUM) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLPSTR (DATA SET 1) MISSING FOR COMPONENT H2S
      A NOMINAL VALUE OF3000. (bar) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLTSTR (DATA SET 1) MISSING FOR COMPONENT H2S
      A NOMINAL VALUE OF415. (K) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLRSTR (DATA SET 1) MISSING FOR COMPONENT H2S
      A NOMINAL VALUE OF736. (KG/CUM) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLPSTR (DATA SET 1) MISSING FOR COMPONENT COS
      A NOMINAL VALUE OF3000. (bar) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLTSTR (DATA SET 1) MISSING FOR COMPONENT COS
      A NOMINAL VALUE OF415. (K) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLRSTR (DATA SET 1) MISSING FOR COMPONENT COS
      A NOMINAL VALUE OF736. (KG/CUM) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLPSTR (DATA SET 1) MISSING FOR COMPONENT N2
      A NOMINAL VALUE OF3000. (bar) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLTSTR (DATA SET 1) MISSING FOR COMPONENT N2
      A NOMINAL VALUE OF415. (K) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLRSTR (DATA SET 1) MISSING FOR COMPONENT N2
      A NOMINAL VALUE OF736. (KG/CUM) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLPSTR (DATA SET 1) MISSING FOR COMPONENT H2O
      A NOMINAL VALUE OF3000. (bar) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLTSTR (DATA SET 1) MISSING FOR COMPONENT H2O
      A NOMINAL VALUE OF415. (K) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLRSTR (DATA SET 1) MISSING FOR COMPONENT H2O
      A NOMINAL VALUE OF736. (KG/CUM) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLPSTR (DATA SET 1) MISSING FOR COMPONENT METHA-01
      A NOMINAL VALUE OF3000. (bar) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLTSTR (DATA SET 1) MISSING FOR COMPONENT METHA-01
      A NOMINAL VALUE OF415. (K) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLRSTR (DATA SET 1) MISSING FOR COMPONENT METHA-01
      A NOMINAL VALUE OF736. (KG/CUM) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLPSTR (DATA SET 1) MISSING FOR COMPONENT S2
      A NOMINAL VALUE OF3000. (bar) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLTSTR (DATA SET 1) MISSING FOR COMPONENT S2
      A NOMINAL VALUE OF415. (K) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLRSTR (DATA SET 1) MISSING FOR COMPONENT S2
      A NOMINAL VALUE OF736. (KG/CUM) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLPSTR (DATA SET 1) MISSING FOR COMPONENT S6
      A NOMINAL VALUE OF3000. (bar) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLTSTR (DATA SET 1) MISSING FOR COMPONENT S6
      A NOMINAL VALUE OF415. (K) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLRSTR (DATA SET 1) MISSING FOR COMPONENT S6
      A NOMINAL VALUE OF736. (KG/CUM) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLPSTR (DATA SET 1) MISSING FOR COMPONENT S8
      A NOMINAL VALUE OF3000. (bar) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLTSTR (DATA SET 1) MISSING FOR COMPONENT S8
      A NOMINAL VALUE OF415. (K) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLRSTR (DATA SET 1) MISSING FOR COMPONENT S8
      A NOMINAL VALUE OF736. (KG/CUM) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLPSTR (DATA SET 1) MISSING FOR COMPONENT SO2
      A NOMINAL VALUE OF3000. (bar) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLTSTR (DATA SET 1) MISSING FOR COMPONENT SO2
      A NOMINAL VALUE OF415. (K) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      SLRSTR (DATA SET 1) MISSING FOR COMPONENT SO2
      A NOMINAL VALUE OF736. (KG/CUM) ASSUMED

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      NRTL BINARY PARAMETERS FOR ALL COMPONENT PAIRS ARE ZERO,
      YOUR RESULTS MAY NOT BE ACCURATE. PLEASE REVIEW AND PROVIDE BINARY
      PARAMETERS AS APPROPRIATE.

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      EQUATION OF STATE MODEL ESRKU HAS MISSING PARAMETERS:
      TBRKU AND ITS DEFAULT TB (DATA SET 1) MISSING FOR COMPONENT S2

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      TBRKU AND ITS DEFAULT TB (DATA SET 1) MISSING FOR COMPONENT S6

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      TBRKU AND ITS DEFAULT TB (DATA SET 1) MISSING FOR COMPONENT S8


->Table Generation begins ...

->Table generation completed


页: [1]