->Calculations begin ...


   Block: B7       Model: HEATX
**ERROR
      INVALID HOT STREAM TEMPERATURE SPECIFICATION
      T-SPEC =3.4315000D+02 IS MORE THAN THIN =3.3536437D+02


   Block: B14      Model: HEATER

   Block: B4       Model: MIXER

   Block: B5       Model: HEATER

   Block: B8       Model: VALVE

   Block: B9       Model: RADFRAC

       RateSep convergence iterations: B9
         Iter   Err/Tol
            0   0.36451E+19
**ERROR
      RATESEP CALCULATIONS FAILED TO CONVERGE
         ITERATIONS DIVERGE


**ERROR
      BLOCK B9 IS NOT IN MASS BALANCE:
      MASS INLET FLOW = 0.94080287E+02, MASS OUTLET FLOW = 0.53150598E+02
      RELATIVE DIFFERENCE = 0.77007013E+00


   Block: B10      Model: HEATER

   Block: B11      Model: FLASH2

   Block: B12      Model: HEATER

   Block: B13      Model: PUMP

> Beginning Convergence Loop $OLVER01 Method: WEGSTEIN

   Block: B3       Model: RADFRAC

       Convergence iterations:
         OL   ML   IL   Err/Tol
          1    1    1   0.47816E-03

   Block: B6       Model: HEATER

   Block: B7       Model: HEATX
**ERROR
      INVALID HOT STREAM TEMPERATURE SPECIFICATION
      T-SPEC =3.4315000D+02 IS MORE THAN THIN =3.3536437D+02


   Block: B14      Model: HEATER

   Block: B4       Model: MIXER

   Block: B5       Model: HEATER

   Block: B8       Model: VALVE

   Block: B9       Model: RADFRAC

       RateSep convergence iterations: B9
         Iter   Err/Tol
            0   0.36451E+19
**ERROR
      RATESEP CALCULATIONS FAILED TO CONVERGE
         ITERATIONS DIVERGE


**ERROR
      BLOCK B9 IS NOT IN MASS BALANCE:
      MASS INLET FLOW = 0.94080295E+02, MASS OUTLET FLOW = 0.53150598E+02
      RELATIVE DIFFERENCE = 0.77007030E+00


   Block: B10      Model: HEATER

   Block: B11      Model: FLASH2

   Block: B12      Model: HEATER

   Block: B13      Model: PUMP

> Loop $OLVER01 Method: WEGSTEIN   Iteration    1
# Converged            Max Err/Tol-0.58409E-08

->Generating block results ...

    Block: B7       Model: HEATX
*   WARNING WHILE GENERATING RESULTS FOR UNIT OPERATIONS BLOCK: "B7" (MODEL:
      "HEATX")
      CALCULATED FEED TEMPERATURE FOR THE HOT SIDE (3.3544573D+02)
      IS INCONSISTENT WITH ITS INLET STREAM VALUE (3.3501118D+02)
      PROBABLE CAUSE: LOOSE FLASH TOLERANCE, OR UPSTREAM BLOCK WITH DIFFERENT
      NPHASE OR PROP SET. THE CALCULATED VALUE WILL BE USED IN CALCULATIONS

**ERROR WHILE GENERATING RESULTS FOR UNIT OPERATIONS BLOCK: "B7" (MODEL:
      "HEATX")
      INVALID HOT STREAM TEMPERATURE SPECIFICATION
      T-SPEC =3.4315000D+02 IS MORE THAN THIN =3.3544573D+02


    Block: B13      Model: PUMP
      INFORMATION WHILE GENERATING RESULTS FOR UNIT OPERATIONS BLOCK: "B13"
      (MODEL: "PUMP")
      NET POSITIVE SUCTION HEAD IS LESS THAN ZERO


->Simulation calculations completed ...



***Warning(s) were issued during Input Translation ***
***Check the Run Status Results for more Information ***


               ***Summary of Simulation Errors***

                   Physical
                   Property         System      Simulation
Terminal Errors      0               0               0
    Severe Errors      0               0               0
         Errors      0               0            13
         Warnings      0               0               2


页: [1]