求大神看一下 ,为啥一直报错
The following Unit Operation blocks werecompleted with errors:
COOLER HEX ABS B3
The following Convergence blocks were
completed with errors:
$OLVER01
The following messages were issued during Input Translation:
INFORMATION
PURE COMPONENT PARAMETERS FOR SOME COMPONENTS ARE RETRIEVED FROM
SDF TABLE.THESE PARAMETERS ARE USED WITH THE ELECNRTL OPTION SET
UNLESS YOU ENTER YOUR OWN PARAMETERS IN PROP-DATA PARAGRAPHS
PARAMETERS RETRIEVED FOR COMPONENT CO2 ARE:
VLBROC
PARAMETERS RETRIEVED FOR COMPONENT H2S ARE:
VLBROC
PARAMETERS RETRIEVED FOR COMPONENT H2O ARE:
VLBROCPLXANT
PARAMETERS RETRIEVED FOR COMPONENT C5H13NO2 ARE:
RKTZRA
*WARNING IN THE 'STREAM' PARAGRAPH WHICH BEGINS ON LINE 182
STREAM NAME: GAS
COMPONENT MOLE FLOWS OF SUBSTREAM: 'MIXED'
ARE NORMALIZED TO THE TOTAL MOLE FLOW VALUE.
*WARNING IN THE 'STREAM' PARAGRAPH WHICH BEGINS ON LINE 186
STREAM NAME: MDEA
COMPONENT MOLE FLOWS OF SUBSTREAM: 'MIXED'
ARE NORMALIZED TO THE TOTAL MOLE FLOW VALUE.
INFORMATION WHILE CHECKING INPUT SPECIFICATIONS
BLOCK NAME: ZAISHENG MODEL NAME: RADFRAC
AN INITIAL TEMPERATURE PROFILE SHOULD BE SPECIFIED
IN SENTENCE 'T-EST' IF 'Q1' AND 'QN' ARE SPECIFIED.
***SEVERE ERROR
THE FOLLOWING STAGES DRIED UP (VAPOR OR LIQUID FLOW APPROACHES 0):
1 12
A LIMIT OF0.10000E-04 * SUM OF FEEDS WAS IMPOSED ON THE FLOW RATES
OR A LIMIT OF0.10000E-04 WAS IMPOSED ON THE STAGE V/L OR L/V RATIO.
** ERROR
FEED HAS 1.63 % VAPOR. OUTLET CONDITIONS MAY BE WRONG.
** ERROR
FEED HAS 1.63 % VAPOR. OUTLET CONDITIONS MAY BE WRONG.
-INFORMATION
NET POSITIVE SUCTION HEAD IS LESS THAN ZERO
** ERROR
BLOCK COOLER IS NOT IN MASS BALANCE:
MASS INLET FLOW = 0.20797106E+04, MASS OUTLET FLOW = 0.20383221E+04
RELATIVE DIFFERENCE = 0.20305182E-01
MAY BE DUE TO A TEAR STREAM OR A STREAM FLOW MAY HAVE
BEEN CHANGED BY A FORTRAN, TRANSFER, OR BALANCE BLOCK
AFTER THE BLOCK HAD BEEN EXECUTED.
** ERROR
INVALID HOT STREAM TEMPERATURE SPECIFICATION
T-SPEC =3.5715000D+02 IS MORE THAN THIN =3.2314993D+02
求大神帮忙看一下
谢谢 只知道泵或是换热器在有相态变化或是有气体的时候特别容易出错,但是我也不知道怎么解决,等老马来解答吧 天际流星飞 发表于 2017-7-14 23:16
只知道泵或是换热器在有相态变化或是有气体的时候特别容易出错,但是我也不知道怎么解决,等老马来解答吧
哦哦我把泵去掉了 可不可以加个好友
{:1106_362:} 本帖最后由 xingguanglueguo 于 2017-7-19 14:35 编辑
按照提示一步步解决吧。物性方法先对了没有?提示说你选的是用于电解质的?进料参数是否合适,组分,温度压力等等。冷却器质量不守恒,是不是选定的哪些物流流量不合理,或者输入的精确度不够,小数点后位数不够,所以对不上。 传个文件看看{:1106_371:}