hhhao0203 发表于 2017-12-31 16:28:51

Aspen7.2模拟溴化锂制冷机时,发生器部分提示缺少Dielectric constant (CPDIEC)

新手,所以遇到了问题自己实在是弄不明白了。希望懂的朋友帮我一下。第一次来论坛咨询,不太懂发帖的规矩。。先谢谢大家了
->Processing input specifications ...

      INFORMATION
      PURE COMPONENT PARAMETERS FOR SOME COMPONENTS ARE RETRIEVED FROM
      SDF TABLE.THESE PARAMETERS ARE USED WITH THE ELECNRTL OPTION SET
      UNLESS YOU ENTER YOUR OWN PARAMETERS IN PROP-DATA PARAGRAPHS

      PARAMETERS RETRIEVED FOR COMPONENT H2O ARE:

         VLBROCPLXANT

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      UNSYMMETRIC ELECTROLYTE NRTL MODEL GMENRTLQ HAS MISSING PARAMETERS:
      Dielectric constant (CPDIEC) MISSING FOR LIBR   & OTHER COMPONENTS.
      CPDIEC OF WATER CALCULATED FROM HELGESON AND KIRKHAM CORRELATION
      (1974) WILL BE ASSUMED.

Flowsheet Analysis :

COMPUTATION ORDER FOR THE FLOWSHEET:
FSQ1

->Calculations begin ...


   Block: FSQ1   Model: HEATX

->Generating block results ...

    Block: FSQ1   Model: HEATX

->Simulation calculations completed ...



***No Warnings were issued during Input Translation ***


               ***Summary of Simulation Errors***

                   Physical
                   Property         System      Simulation
Terminal Errors      0               0               0
    Severe Errors      0               0               0
         Errors      0               0               0
         Warnings      1               0               0


jjzg2004 发表于 2017-12-31 16:28:51

{:1106_382:}

windows98 发表于 2017-12-31 16:28:51

如果你能够将模拟文件发送上来,也许大家可以帮你

ma730060 发表于 2017-12-31 16:28:51

关注一下。{:1106_365:}
页: [1]