hzjdlsw 发表于 2009-10-15 15:40:24

aspen中的错误分析

在用ASPEN计算中出现下面错误,请给与分析:
Block: H2O      Model: RADFRAC
       Convergence iterations:
         Iter   Err/Tol
            0      70151.
            1      66623.
            2      64335.
            3      62733.
            4      61996.
            5      61915.
            6   0.61612E+06
            7   0.62778E+06
            8   0.59673E+06
            9   0.46793E+06
             10   0.28867E+06
             11   0.19825E+06
             12   0.20517E+06
             13   0.22248E+06
             14   0.38430E+06
             15   0.53698E+06
             16   0.57822E+06
             17   0.25408E+06
*** SEVERE ERROR
      MATERIAL AND ENERGY BALANCES FAILED TO CONVERGE: CHECK COL-SPECS
      OR SUPPLY BETTER TEMPERATURE AND COMPOSITION ESTIMATES.
**ERROR
      SOME ROWS COMPLETED WITH ERRORS.

->Simulation calculations completed ...

                        ***Summary of Errors***
                   Physical
                   Property         System      Simulation
Terminal Errors      0               0               0
    Severe Errors      0               0               2
         Errors      0               0               1
         Warnings      0               0               0
->Generating results ...

Horse 发表于 2009-10-15 15:44:05

似乎是不平衡吧,物料不平衡或者能量不平衡。

可能是输入太多的条件,,导致前后矛盾了

lsrwan 发表于 2009-10-15 18:18:24

光这些信息根本分析不出任何东西了,得具体到你的例子。

TOMMORROW 发表于 2009-11-4 14:56:43

前后无法平衡,无法收敛

lalaxe 发表于 2009-11-4 17:03:49

由于不知何缘故,我在此版块发不了贴,借宝地一用!
我用ASPEN做了简单的模拟,在未进行灵敏度计算之前,一切正常,也得出结果,但是在
进行灵敏度计算时,报错了,我也解决不了,而且我也上传不了原文件,只好说明大致情况:
我是想模拟塔板数与回流比的关系,设置的因变量塔板数,是模块变量:NSTAGE,操作变
量是回流比,也是模块变量:RR,上下限0.2~3,请高手赐教诊断!!!!
关于变量我想再问一下,NSTAGE和ACT-STAGES有何区别?
如果需要原文件,请留emai或QQ,我发过去,谢谢!!
页: [1]