lsd516888 发表于 2018-4-6 12:42:48

来自一个aspen新手的求救,关于循环

现在能看出来的问题是,我怎么调分离器的参数,分离出来的水的量都不变。。一脸懵file:///C:/Users/刘帅东/Desktop/1.png逼,不知道怎么搞。。。。
*   WARNING
      CONVERGENCE BLOCK $OLVER01 NOT CONVERGED IN 30 ITERATIONS   7 vars not converged, Max Err/Tol   0.37975E+03
>> Loop $OLVER01 exceeded maximum iterations.   Block: B9       Model: HEATER**ERROR
      BLOCK B11 IS NOT IN MASS BALANCE:
      MASS INLET FLOW = 0.10521520E+01, MASS OUTLET FLOW = 0.10377903E+01
      RELATIVE DIFFERENCE = 0.13838754E-01
      MAY BE DUE TO A TEAR STREAM OR A STREAM FLOW MAY HAVE
      BEEN CHANGED BY A FORTRAN, TRANSFER, OR BALANCE BLOCK
      AFTER THE BLOCK HAD BEEN EXECUTED.**ERROR
      Convergence block $OLVER01 did not converge
      normally in the final pass

lsd516888 发表于 2018-4-6 12:42:48

附加图片,谢谢大家了,自己好蠢啊
页: [1]
查看完整版本: 来自一个aspen新手的求救,关于循环