kikiu 发表于 2018-4-20 15:34:56

如何解决aspen8.6版本运行甲醇三塔精馏时出现报错?NaOH物理参数异常,第三个塔出...

本帖最后由 kikiu 于 2018-4-20 15:38 编辑

文件是前几天论坛里找到的
aspen几年前学过,今年做毕业设计便又花了点时间装上,发现已经不懂这个软件了……
双手合十,诚心求助


The following Unit Operation blocks were
completed with errors:
D-703

The following messages were issued during Input Translation:

*WARNING IN PHYSICAL PROPERTY SYSTEM
   PARAMETER PLXANT (DATA SET 1) FOR COMPONENT NAOH:
   UNREASONABLE VAPOR PRESSURE CALCULATED AT NORMAL BOILING POINT.
   VALUE SHOULD BE WITHIN 10% OF 1D5 N/SQM.PLEASE CHECK YOUR INPUT
   FOR THE ANTOINE PARAMETERS.

*WARNING IN THE 'STREAM' PARAGRAPH WHICH BEGINS ON LINE 180
   STREAM NAME: 702
   COMPONENT MASS FRACTIONS ARE NORMALIZED TO UNITY.

*WARNING IN THE 'STREAM' PARAGRAPH WHICH BEGINS ON LINE 193
   STREAM NAME: NAOH
   COMPONENT MASS FRACTIONS ARE NORMALIZED TO UNITY.
页: [1]
查看完整版本: 如何解决aspen8.6版本运行甲醇三塔精馏时出现报错?NaOH物理参数异常,第三个塔出...