liuzhuo518 发表于 2018-11-18 11:48:06

CADWorx2013自定义T型三通隔膜阀出ISO时报错,哪位大神能帮忙解决

我自定义的T型宝德的膈膜三通阀,绘制图纸没有问题,但出ISO时报错,两通的没有问题,报错内容如下:
Errors were generated during ISOGEN export.
Review the ISOGEN Message File to resolve these errors.
-------------------------------------------------------------
Personal ISOGEN failed while running IDFGEN module

IDFGEN failed processing the PCF
-------------------------------------------------------------

Personal ISOGEN : VERSION 8.1.0 (Full)

*** IDFGEN VERSION 9.1.0 (Build 14) ***
Reading File: ISOGEN.PCF

Processing PIPELINE-REFERENCE: 1/2"-BPE

ERRORS/WARNINGS DETECTED IN PIPE /1/2"-BPE
********************************************************************************
ERROR:
Message Identifier:             IDFGEN:18
Component Type:               VALVE-3WAY
Unique Component Identifier:    08602A15-5008-4837-AE93-7EFD774C6681
Item Code:                      1
Coordinates:                  200.15    156.68    0
PCF Line Number:                23
Message Text:                   INCORRECT ENTRIES FOR THE FOLLOWING MANDATORY ITEM
                              'CENTRE-POINT'
********************************************************************************
ERROR:
Message Identifier:             IDFGEN:1
Message Text:                   *** SEVERE ERROR - PIPELINE REJECTED ***
********************************************************************************
ERROR:
Message Identifier:             IDFGEN:61
Message Text:                   UNEXPECTED ERROR
********************************************************************************

哪位遇到这样的问题,请帮忙解决一下,谢谢。。。

liuzhuo518 发表于 2018-11-18 11:48:06

自己顶一下,这个问题研究了半个月了,还是没有解决

woxinzhufeng 发表于 2018-11-18 11:48:06

你三通阀怎么做异径的?
页: [1]
查看完整版本: CADWorx2013自定义T型三通隔膜阀出ISO时报错,哪位大神能帮忙解决