馨逸 发表于 2019-6-6 23:54:54

Aspen求助

Loop $OLVER01 Method: WEGSTEIN   Iteration   27
Converging tear streams: S1
   3 vars not converged, Max Err/Tol   0.49999E+09

   Block: B2       Model: HEATX
**ERROR
      "COLD" STREAM IS HOTTER THAN "HOT" STREAM
      BLOCK BYPASSED


   Block: B8       Model: FLASH3

   Block: B9       Model: PUMP

   Block: B10      Model: MIXER

   Block: B1       Model: RADFRAC

       Convergence iterations:
         OL   ML   IL   Err/Tol
          1    1   10   0.17871E+07
          2    1   10      8166.5
          3    1    7      1123.4
          4    1   10      476.15
          5    1   10      331.35
          6    1   10      305.93
          7    1   10      787.33
*** SEVERE ERROR
      THE FOLLOWING STAGES DRIED UP (VAPOR OR LIQUID FLOW APPROACHES 0):
      6    7   10
      A LIMIT OF0.10000E-04 * SUM OF FEEDS WAS IMPOSED ON THE FLOW RATES
      OR A LIMIT OF0.10000E-04 WAS IMPOSED ON THE STAGE V/L OR L/V RATIO.


> Loop $OLVER01 Method: WEGSTEIN   Iteration   28
Converging tear streams: S1
19 vars not converged, Max Err/Tol   0.19750E+05

   Block: B2       Model: HEATX
**ERROR
      "COLD" STREAM IS HOTTER THAN "HOT" STREAM
      BLOCK BYPASSED


   Block: B8       Model: FLASH3

   Block: B9       Model: PUMP

   Block: B10      Model: MIXER

   Block: B1       Model: RADFRAC

       Convergence iterations:
         OL   ML   IL   Err/Tol
          1    1   10      21069.
          2    1    4      2035.7
          3    1    4      176.08
*** SEVERE ERROR
      THE FOLLOWING STAGES DRIED UP (VAPOR OR LIQUID FLOW APPROACHES 0):
      5    6    7    8    9   10
      A LIMIT OF0.10000E-04 * SUM OF FEEDS WAS IMPOSED ON THE FLOW RATES
      OR A LIMIT OF0.10000E-04 WAS IMPOSED ON THE STAGE V/L OR L/V RATIO.


> Loop $OLVER01 Method: WEGSTEIN   Iteration   29
Converging tear streams: S1
14 vars not converged, Max Err/Tol-0.10000E+05

   Block: B2       Model: HEATX
**ERROR
      INVALID HOT STREAM TEMPERATURE SPECIFICATION
      T-SPEC =3.2758000D+02 IS MORE THAN THIN =3.0615000D+02


   Block: B8       Model: FLASH3

   Block: B9       Model: PUMP

   Block: B10      Model: MIXER

   Block: B1       Model: RADFRAC

       Convergence iterations:
         OL   ML   IL   Err/Tol
          1    1   10      216.88
          2    1   10      109.39
          3   12   28      51.417
*** SEVERE ERROR
      THE FOLLOWING STAGES DRIED UP (VAPOR OR LIQUID FLOW APPROACHES 0):
      2    3    5    6    7    8    9   10
      A LIMIT OF0.10000E-04 * SUM OF FEEDS WAS IMPOSED ON THE FLOW RATES
      OR A LIMIT OF0.10000E-04 WAS IMPOSED ON THE STAGE V/L OR L/V RATIO.


> Loop $OLVER01 Method: WEGSTEIN   Iteration   30
Converging tear streams: S1
*   WARNING
      CONVERGENCE BLOCK $OLVER01 NOT CONVERGED IN 30 ITERATIONS

14 vars not converged, Max Err/Tol-0.10000E+05

**ERROR
      BLOCK B1 IS NOT IN MASS BALANCE:
      MASS INLET FLOW = 0.15430546E+03, MASS OUTLET FLOW = 0.15668997E+03
      RELATIVE DIFFERENCE = 0.15453185E-01
      MAY BE DUE TO A TEAR STREAM OR A STREAM FLOW MAY HAVE
      BEEN CHANGED BY A FORTRAN, TRANSFER, OR BALANCE BLOCK
      AFTER THE BLOCK HAD BEEN EXECUTED.

**ERROR
      Convergence block $OLVER01 did not converge
      normally in the final pass


->Generating block results ...

    Block: B2       Model: HEATX
*   WARNING WHILE GENERATING RESULTS FOR UNIT OPERATIONS BLOCK: "B2" (MODEL:
      "HEATX")
      CALCULATED FEED TEMPERATURE FOR THE COLD SIDE (2.5531554D+02)
      IS INCONSISTENT WITH ITS INLET STREAM VALUE (2.3544202D+02)
      PROBABLE CAUSE: LOOSE FLASH TOLERANCE, OR UPSTREAM BLOCK WITH DIFFERENT
      NPHASE OR PROP SET. THE CALCULATED VALUE WILL BE USED IN CALCULATIONS

**ERROR WHILE GENERATING RESULTS FOR UNIT OPERATIONS BLOCK: "B2" (MODEL:
      "HEATX")
      INVALID HOT STREAM TEMPERATURE SPECIFICATION
      T-SPEC =3.2758000D+02 IS MORE THAN THIN =3.0615000D+02


    Block: B9       Model: PUMP

->Simulation calculations completed ...
哪里错了呢

zhangjx73 发表于 2019-6-6 23:54:54

楼主的错误太多了,建议多看看ASPEN资料书,从基本功做起

gong5073489 发表于 2019-6-6 23:54:54

好多错误的。换热器X,塔问题,不收敛。等等。你这应该不是一个问题导致的。。

542925680 发表于 2019-6-6 23:54:54

错误很多啊,你可以一个模块一个模块的调试,改正。

ftecagan247 发表于 2019-6-6 23:54:54

{:530:}{:530:}{:526:}{:526:}

huweijilian 发表于 2019-6-6 23:54:54

"COLD" STREAM IS HOTTER THAN "HOT" STREAM
BLOCK BYPASSED
- 本文出自马后炮化工-让天下没有难学的化工技术,原文地址:https://meng.horse/thread-213989-1-1.html
冷物料比热物料温度高,物流接反了

wangminhao1 发表于 2019-6-6 23:54:54

radfrac塔的进水流量可能太小,或者可能塔板的设置,水流和气流进入塔板设置错误;

hgw04044217 发表于 2019-6-6 23:54:54

文件不上传,没人能具体帮你。