能动能不能动 发表于 2021-4-15 22:47:38

Aspen中出现警告但数据几乎全对得上,还有保存的时候弹出Aspen EDR窗口是怎么回事

如题,在保存的时候弹出了如图片显示的窗口,请问有影响吗?控制面板显示信息如下,显示出现了一个错误,但是查看1RSTOIC模块的时候,数据和选项都按照书上的操作,并无错误
求各位大佬指点

<< 正在加载模拟引擎 21:38:15 Thu Apr 15, 2021>>



->Processing input specifications ...


->Table Generation begins ...

->Table generation completed

<<运行保存>>



->Processing input specifications ...

**ERROR WHILE CHECKING INPUT SPECIFICATIONS
      BLOCK NAME: 1RSTOIC    MODEL NAME: RSTOIC
      REACTION NUMBER "2" DOES NOT SATISFY MASS BALANCE.
      THE ABSOLUTE ERROR IS   14.027
      CHECK STOICHIOMETRY/MOLECULAR WEIGHTS.

! Errors while processing input specifications


->Processing input specifications ...

Flowsheet Analysis :

COMPUTATION ORDER FOR THE FLOWSHEET:
0DUPL 1RSTOIC 2RYELD

->Calculations begin ...


   Block: 0DUPL    Model: DUPL

   Block: 1RSTOICModel: RSTOIC

   Block: 2RYELD   Model: RYIELD
*   WARNING
      SPECIFIED YIELDS HAVE BEEN NORMALIZED BY A FACTOR OF (15916.1)
      TO MAINTAIN AN OVERALL MATERIAL BALANCE.


->Simulation calculations completed ...



***No Warnings were issued during Input Translation ***


               ***Summary of Simulation Errors***

                   Physical
                   Property         System      Simulation
Terminal Errors      0               0               0
    Severe Errors      0               0               0
         Errors      0               0               0
         Warnings      0               0               1

->Generating results ...



->Processing input specifications ...

Flowsheet Analysis :

COMPUTATION ORDER FOR THE FLOWSHEET:
0DUPL 1RSTOIC 2RYELD

->Calculations begin ...


   Block: 0DUPL    Model: DUPL

   Block: 1RSTOICModel: RSTOIC

   Block: 2RYELD   Model: RYIELD
*   WARNING
      SPECIFIED YIELDS HAVE BEEN NORMALIZED BY A FACTOR OF (15916.1)
      TO MAINTAIN AN OVERALL MATERIAL BALANCE.


->Simulation calculations completed ...



***No Warnings were issued during Input Translation ***


               ***Summary of Simulation Errors***

                   Physical
                   Property         System      Simulation
Terminal Errors      0               0               0
    Severe Errors      0               0               0
         Errors      0               0               0
         Warnings      0               0               1

->Generating results ...

<reset scope>
<reset scope>

<< Problem specifications modified 22:28:11 Thu Apr 15, 2021>>


->Processing input specifications ...


->Finished processing new specifications


->Calculations begin ...


   Block: 2RYELD   Model: RYIELD
*   WARNING
      SPECIFIED YIELDS HAVE BEEN NORMALIZED BY A FACTOR OF (15916.1)
      TO MAINTAIN AN OVERALL MATERIAL BALANCE.


->Simulation calculations completed ...



***No Warnings were issued during Input Translation ***


               ***Summary of Simulation Errors***

                   Physical
                   Property         System      Simulation
Terminal Errors      0               0               0
    Severe Errors      0               0               0
         Errors      0               0               0
         Warnings      0               0               2

->Generating results ...


<< Run Saved >>


<<运行保存>>


<< Run Saved >>


<<运行保存>>

<< Run Saved >>


<<运行保存>>





能动能不能动 发表于 2021-4-15 22:47:38

顶个贴,求大佬们帮忙看看

banknation 发表于 2021-4-15 22:47:38

最好不要用中文路径,另外,也不要使用带有中文的模板

能动能不能动 发表于 2021-4-15 22:47:38

banknation 发表于 2021-4-18 17:51
最好不要用中文路径,另外,也不要使用带有中文的模板

好的,我再试试,谢谢
页: [1]