17692393003 发表于 2021-4-19 22:55:49

马友们,这个设计规范怎么加呀,一直错误,可以帮帮我吗

我想通过调节流股11的温度使换热器HX1和HX2热负荷绝对值相等,别的流程没问题,但是设计规范收敛不了
The following Convergence blocks were
completed with errors:
$OLVER03

The following messages were issued during Input Translation:

*WARNING WHILE CHECKING INPUT SPECIFICATIONS FOR VARIED VARIABLE IN
   DESIGN-SPEC: 'DS-1'
   YOU ARE VARYING A VARIABLE OF AN INTERMEDIATE STREAM
   STREAM RESULTS MAY BE INCONSISTENT WITH THE BLOCK UPSTREAM

*WARNING WHILE CHECKING INPUT SPECIFICATIONS
   INCONSISTENT FREE WATER SETTING DETECTED FOR 2 STREAMS
   SOURCE BLOCK      FREE WATER STREAM   DESTINATION BLOCK   FREE WATER
   =================== ========== ======== =================== ==========
   B8                  YES      31       ABSORBER            NO
   B7                  NO         18       B8                  YES

bceio 发表于 2021-4-19 22:55:49

上下限,起始点,关注一下。另外是否是否独立变量或者有其他关联。

凉皮太烫 发表于 2021-4-19 22:55:49

设计规定用HX2的进口温度做变量,但你的流程好像控制不了HX2进料的温度,试试在HX2前面加个加热器,变量改成加热器负荷或者出口温度