ziondi 发表于 2021-4-28 10:13:37

分馏塔模拟不收敛

分馏塔模拟后不收敛
proii模拟后的message是这样的
** WARNING **The liquid enthalpy of H2O at temperature 805.15 K is outside
               the acceptable range of 273.16 K through 533.15 K.
** WARNING **The liquid enthalpy of BUTANE at temperature 805.15 K is
               outside the acceptable range of 134.86 K through 420 K.
** WARNING **The liquid enthalpy of HEXANE at temperature 805.15 K is
               outside the acceptable range of 177.83 K through 460 K.
** WARNING **Cp calculated for stream 244 is less than zero. Results can be
               erroneous. Use some other suitable enthalpy corelation.
    FEED FLASH    COMPLETE
    UNIT   11   BEGINS   - 'E1          '
** WARNING **The LMTD correction factor (FT) has been set to 0.0001.
    UNIT   11   SOLVED
    UNIT    9   BEGINS   - 'T1          '
** WARNING **UNIT 9, 'T1' - Stream 401 - The given FIXED STREAM RATE
               (80.207) and the PRODUCT RATE ESTIMATE (1283.5) were DIFFERENT,
               so the rate estimate has been changed to 80.207.
** WARNING **UNIT 9, 'T1' - Stream 301 - The given FIXED STREAM RATE
               (.38069) and the PRODUCT RATE ESTIMATE (2955.8) were DIFFERENT,
               so the rate estimate has been changed to .38069.
** WARNING **UNIT 9, 'T1' - Stream 241 - The given FIXED STREAM RATE
               (.12683) and the PRODUCT RATE ESTIMATE (7623.3) were DIFFERENT,
               so the rate estimate has been changed to .12683.
** WARNING **UNIT 9, 'T1' - Stream 202A - The given FIXED STREAM RATE
               (1.1135E-21) and the PRODUCT RATE ESTIMATE (3377.2) were
               DIFFERENT, so the rate estimate has been changed to 1.1135E-21.
** WARNING **UNIT 9, 'T1' - COLUMN calculations are DIVERGING. Check input
               data for consistency.
*** A FATAL ERROR OCCURRED ON ITERATION    1
*** ERROR HISTORY IS NOT AVAILABLE FOR THIS ITERATION
    UNIT    9 NOT SOLVED
*** PROBLEM SOLUTION NOT REACHED
***
*** GLOBAL DEVIATION   13.77 MOLE PERCENT
*** MAXIMUM DEVIATION ON COMPONENT PENTANE OF   24.77 MOLE PERCENT
***
** WARNING **Unit 'T1' DID NOT SOLVE
*** Run completed - Case not solved

*** THIS RUN USED 49.36 PRO/II SIMULATION UNITS

*** RUN STATISTICS
    STARTED    09:59:19 04/28/21          NO ERRORS
    FINISHED   09:59:23 04/28/21          29 WARNINGS
    RUN TIMES                           NO MESSAGES
      INTERACTIVE   0 MIN,0.00 SEC
      CALCULATIONS    0 MIN,3.95 SEC
      TOTAL         0 MIN,3.95 SEC
** WARNING **PROBLEM SOLUTION NOT REACHED. ** Note- Default Tolerances in
               unit specifications, recycle loops and columns are tightened
               starting with PRO/II 9.4. If the file is happened to converge
               in previous version, probable reason for non-convergence could
               be tightened tolerance in current version.

*** CHECKING
    UNIT DATA
    EXECUTION SEQUENCE
    FEED FLASH CONDITIONS
      R                                 
PRO/IIVersion 9.4 - Calculation module
========================================

*** READING PRO/II DATABASE
    PROJECT                   USER
    PROBLEM                   DATE04/06/21

*** PROBLEM SOLUTION BEGINS
    FEED FLASH    BEGINS
** WARNING **The liquid enthalpy of N2 at temperature 366.15 K is outside
               the acceptable range of 63.15 K through 112 K.
** WARNING **The liquid enthalpy of CO at temperature 366.15 K is outside
               the acceptable range of 68.15 K through 132 K.
** WARNING **The liquid enthalpy of CO2 at temperature 366.15 K is outside
               the acceptable range of 220 K through 290 K.
** WARNING **The liquid enthalpy of H2 at temperature 366.15 K is outside
               the acceptable range of 13.95 K through 32 K.
** WARNING **The liquid enthalpy of METHANE at temperature 366.15 K is
               outside the acceptable range of 90.69 K through 190 K.
** WARNING **The liquid enthalpy of ETHYLENE at temperature 366.15 K is
               outside the acceptable range of 103.97 K through 252.7 K.
** WARNING **The liquid enthalpy of ETHANE at temperature 366.15 K is
               outside the acceptable range of 92 K through 290 K.
** WARNING **The liquid enthalpy of PROPENE at temperature 366.15 K is
               outside the acceptable range of 87.89 K through 298.15 K.
** WARNING **The liquid enthalpy of PROPANE at temperature 366.15 K is
               outside the acceptable range of 85.47 K through 360 K.
** WARNING **The liquid enthalpy of IBUTENE at temperature 366.15 K is
               outside the acceptable range of 132.81 K through 343.15 K.
** WARNING **The liquid enthalpy of 1BUTENE at temperature 366.15 K is
               outside the acceptable range of 87.8 K through 300 K.
** WARNING **The liquid enthalpy of T2BUTENE at temperature 366.15 K is
               outside the acceptable range of 167.62 K through 274.03 K.
** WARNING **The liquid enthalpy of C2BUTENE at temperature 366.15 K is
               outside the acceptable range of 134.26 K through 350 K.
** WARNING **The liquid enthalpy of 1PENTENE at temperature 366.15 K is
               outside the acceptable range of 107.93 K through 310 K.
** WARNING **The liquid enthalpy of IPENTANE at temperature 366.15 K is
               outside the acceptable range of 113.25 K through 310 K.
** WARNING **The liquid enthalpy of H2S at temperature 416.15 K is outside
               the acceptable range of 187.68 K through 370 K.
** WARNING **The liquid enthalpy of IBUTANE at temperature 416.15 K is
               outside the acceptable range of 113.54 K through 380 K.
** WARNING **The liquid enthalpy of PENTANE at temperature 416.15 K is
               outside the acceptable range of 143.42 K through 390 K.
** WARNING **The liquid enthalpy of H2O at temperature 805.15 K is outside
               the acceptable range of 273.16 K through 533.15 K.
** WARNING **The liquid enthalpy of BUTANE at temperature 805.15 K is
               outside the acceptable range of 134.86 K through 420 K.
** WARNING **The liquid enthalpy of HEXANE at temperature 805.15 K is
               outside the acceptable range of 177.83 K through 460 K.
** WARNING **Cp calculated for stream 244 is less than zero. Results can be
               erroneous. Use some other suitable enthalpy corelation.
    FEED FLASH    COMPLETE
    UNIT   11   BEGINS   - 'E1          '
** WARNING **The LMTD correction factor (FT) has been set to 0.0001.
    UNIT   11   SOLVED
    UNIT    9   BEGINS   - 'T1          '
            INNER0 : E(ENTH+SPEC) =1.61376E-01
            CALCULATING NEW MATRIX
            INNER1 : E(ENTH+SPEC) =1.61365E-01ALPHA =9.89537E-05
            INNER2 : E(ENTH+SPEC) =1.61346E-01ALPHA =7.78588E-04
            INNER3 : E(ENTH+SPEC) =1.61350E-01ALPHA =4.50298E-05
            INNER4 : E(ENTH+SPEC) =1.61354E-01ALPHA =7.56096E-06
      ITER1 E(K) =1.806E+00 E(ENTH+SPEC) =1.614E-01E(SUM) =2.531E+01
            DAMP =1.000E+00
            INNER0 : E(ENTH+SPEC) =1.62677E-01
            INNER1 : E(ENTH+SPEC) =1.62678E-01ALPHA =4.82446E-06
            INNER2 : E(ENTH+SPEC) =1.62682E-01ALPHA =8.20466E-06
            INNER3 : E(ENTH+SPEC) =1.62684E-01ALPHA =4.37230E-06
            INNER4 : E(ENTH+SPEC) =1.62685E-01ALPHA =2.03671E-06
            CALCULATING NEW MATRIX
            INNER1 : E(ENTH+SPEC) =1.62685E-01ALPHA =2.81318E-13
            INNER2 : E(ENTH+SPEC) =1.62685E-01ALPHA =3.44795E-13
            INNER3 : E(ENTH+SPEC) =1.62685E-01ALPHA =3.21155E-13
            INNER4 : E(ENTH+SPEC) =1.62685E-01ALPHA =2.52753E-14
            CALCULATING NEW MATRIX
            INNER1 : E(ENTH+SPEC) =1.62685E-01ALPHA =7.67658E-13
            INNER2 : E(ENTH+SPEC) =1.62685E-01ALPHA =3.23288E-13
            INNER3 : E(ENTH+SPEC) =1.62685E-01ALPHA =3.17754E-13
            INNER4 : E(ENTH+SPEC) =1.62685E-01ALPHA =2.67711E-14
            CALCULATING NEW MATRIX
            INNER1 : E(ENTH+SPEC) =1.62685E-01ALPHA =6.55025E-13
            INNER2 : E(ENTH+SPEC) =1.62685E-01ALPHA =6.21049E-15
            INNER3 : E(ENTH+SPEC) =1.62685E-01ALPHA =1.41148E-15
            INNER4 : E(ENTH+SPEC) =1.62685E-01ALPHA =6.70924E-16
            CALCULATING NEW MATRIX
** WARNING **UNIT 9, 'T1' - COLUMN calculations are DIVERGING. Check input
               data for consistency.
*** A FATAL ERROR OCCURRED ON ITERATION    2
*** ERROR HISTORY IS NOT AVAILABLE FOR THIS ITERATION
    UNIT    9 NOT SOLVED
*** PROBLEM SOLUTION NOT REACHED
***
*** GLOBAL DEVIATION   13.79 MOLE PERCENT
*** MAXIMUM DEVIATION ON COMPONENT PENTANE OF   24.70 MOLE PERCENT
***
** WARNING **Unit 'T1' DID NOT SOLVE
*** Run completed - Case not solved

*** THIS RUN USED 49.36 PRO/II SIMULATION UNITS

*** RUN STATISTICS
    STARTED    10:03:06 04/28/21          NO ERRORS
    FINISHED   10:03:10 04/28/21          25 WARNINGS
    RUN TIMES                           NO MESSAGES
      INTERACTIVE   0 MIN,0.00 SEC
      CALCULATIONS    0 MIN,4.56 SEC
      TOTAL         0 MIN,4.56 SEC
** WARNING **PROBLEM SOLUTION NOT REACHED. ** Note- Default Tolerances in
               unit specifications, recycle loops and columns are tightened
               starting with PRO/II 9.4. If the file is happened to converge
               in previous version, probable reason for non-convergence could
               be tightened tolerance in current version.
希望大家能够帮忙看看

凉皮太烫 发表于 2021-4-28 10:13:37

500多℃超过了物性范围吧?