man穆瑞 发表于 2022-4-21 10:24:10

AspenPlus模拟有警告结果可用

这个问题是什么,要怎么解决啊,提示有警告但结果可用
The following Unit Operation blocks were
completed with warnings:
T2

The following messages were issued during Input Translation:

   INFORMATION
   THERE ARE HENRY COMPONENTS DEFINED IN THIS CASE, THE BINARY DATABANK
   WILL BE SEARCHED AUTOMATICALLY FOR ANY AVAILABLE HENRY CONSTANTS.

   INFORMATION IN PHYSICAL PROPERTY SYSTEM
   THE PAIR PARAMETERS FOR ELECNRTL OPTION SET HAS BEEN RETRIEVED FROM
   DATABANK ENRTL-RK.

   INFORMATION
   PURE COMPONENT PARAMETERS FOR SOME COMPONENTS ARE RETRIEVED FROM
   DATABANK ELECPURE. THESE PARAMETERS ARE USED WITH ELECNRTL METHOD.
   UNLESS YOU ENTER YOUR OWN PARAMETERS IN PROP-DATA PARAGRAPHS.
   PARAMETER RKTZRA RETRIEVED FOR COMPONENT MDEA
   PARAMETER RKTZRA RETRIEVED FOR COMPONENT MEA
   PARAMETER DHFORM RETRIEVED FOR COMPONENT MEA
   PARAMETER THRSWT(ELEMENT/3) RETRIEVED FOR COMPONENT MEA
   PARAMETER VLBROC RETRIEVED FOR COMPONENT CO2
   PARAMETER CPDIEC RETRIEVED FOR COMPONENT MDEA
   PARAMETER PLXANT RETRIEVED FOR COMPONENT H2O
   PARAMETER THRSWT(ELEMENT/3) RETRIEVED FOR COMPONENT H2O
   PARAMETER PLXANT RETRIEVED FOR COMPONENT MEA
   PARAMETER CPDIEC RETRIEVED FOR COMPONENT MEA

*WARNING IN THE 'STREAM' PARAGRAPH WHICH BEGINS ON LINE 347
   STREAM NAME: FEED
   COMPONENT MOLE FRACTIONS ARE NORMALIZED TO UNITY.

这个问题是什么,要怎么解决啊,提示有警告但结果可用

liming730 发表于 2022-4-21 10:24:10

你这个不算是问题,只不过输入组分的分率不归一,程序自动归一。

man穆瑞 发表于 2022-4-21 10:24:10

liming730 发表于 2022-4-21 19:40
你这个不算是问题,只不过输入组分的分率不归一,程序自动归一。

好,那就不需要管他了,谢谢
页: [1]
查看完整版本: AspenPlus模拟有警告结果可用