娟子0923 发表于 2010-11-22 14:38:12

请教:在aspenplus中亚磷酸三邻甲苯酯(C21H21O3P)的物性参数的估算

请教:在aspenplus中亚磷酸三邻甲苯酯(C21H21O3P)的物性参数的估算。
在进行模拟时,出现以下结果:
Processing input specifications ...
*   WARNING IN PHYSICAL PROPERTY SYSTEM
      FUNCTIONAL GROUP GENERATION FOR THE UNIF-LBY METHOD CANNOT BE COMPLETED
      FOR COMPONENT CHOP.THE FOLLOWING ATOMS WERE NOT MATCHED:
      P 1O 2O 3O 4
                     THE FUNCTIONAL GROUPS GENERATED
          GROUP NUMBERNO. OF OCCUR.   GROUP NUMBERNO. OF OCCUR.
               1105         12               1100          6
               1015          3
*   WARNING IN PHYSICAL PROPERTY SYSTEM
      FUNCTIONAL GROUP GENERATION FOR THE UNIF-DMD METHOD CANNOT BE COMPLETED
      FOR COMPONENT CHOP.THE FOLLOWING ATOMS WERE NOT MATCHED:
      P 1O 2O 3O 4
                     THE FUNCTIONAL GROUPS GENERATED
          GROUP NUMBERNO. OF OCCUR.   GROUP NUMBERNO. OF OCCUR.
               1160          3               1105         12
               1100          3
*   WARNING IN PHYSICAL PROPERTY SYSTEM
      FUNCTIONAL GROUP GENERATION FOR THE JOBACK METHOD CANNOT BE COMPLETED
      FOR COMPONENT CHOP.THE FOLLOWING ATOMS WERE NOT MATCHED:
      P 1
                     THE FUNCTIONAL GROUPS GENERATED
          GROUP NUMBERNO. OF OCCUR.   GROUP NUMBERNO. OF OCCUR.
                121          3                  100          3
                113         12                  114          6
*   WARNING IN PHYSICAL PROPERTY SYSTEM
      FUNCTIONAL GROUP GENERATION FOR THE LYDERSEN METHOD CANNOT BE COMPLETED
      FOR COMPONENT CHOP.THE FOLLOWING ATOMS WERE NOT MATCHED:
      P 1
                     THE FUNCTIONAL GROUPS GENERATED
          GROUP NUMBERNO. OF OCCUR.   GROUP NUMBERNO. OF OCCUR.
                100          3                  114         12
                115          6                  123          3
*   WARNING IN PHYSICAL PROPERTY SYSTEM
      FUNCTIONAL GROUP GENERATION FOR THE AMBROSE METHOD CANNOT BE COMPLETED
      FOR COMPONENT CHOP.THE FOLLOWING ATOMS WERE NOT MATCHED:
      P 1
                     THE FUNCTIONAL GROUPS GENERATED
          GROUP NUMBERNO. OF OCCUR.   GROUP NUMBERNO. OF OCCUR.
                145          3                  142          3
                143          3                  134          3
                100          3                  106          3
*   WARNING IN PHYSICAL PROPERTY SYSTEM
      FUNCTIONAL GROUP GENERATION FOR THE GANI METHOD CANNOT BE COMPLETED
      FOR COMPONENT CHOP.THE FOLLOWING ATOMS WERE NOT MATCHED:
      P 1O 2O 3O 4
                     THE FUNCTIONAL GROUPS GENERATED
          GROUP NUMBERNO. OF OCCUR.   GROUP NUMBERNO. OF OCCUR.
               1160          3               1105         12
               1100          3
*   WARNING IN PHYSICAL PROPERTY SYSTEM
      FUNCTIONAL GROUP GENERATION FOR THE FEDORS METHOD CANNOT BE COMPLETED
      FOR COMPONENT CHOP.THE FOLLOWING ATOMS WERE NOT MATCHED:
      P 1
                     THE FUNCTIONAL GROUPS GENERATED
          GROUP NUMBERNO. OF OCCUR.   GROUP NUMBERNO. OF OCCUR.
                116          3                  100          3
                105         12                  106          6
                146          3                  149          3
*   WARNING IN PHYSICAL PROPERTY SYSTEM
      FUNCTIONAL GROUP GENERATION FOR THE BENSON METHOD CANNOT BE COMPLETED
      FOR COMPONENT CHOP.THE FOLLOWING ATOMS WERE NOT MATCHED:
      P 1O 2O 3O 4
                     THE FUNCTIONAL GROUPS GENERATED
          GROUP NUMBERNO. OF OCCUR.   GROUP NUMBERNO. OF OCCUR.
                148          3                  197          3
                137          3                  136         12
                125          3
*   WARNING IN PHYSICAL PROPERTY SYSTEM
      FUNCTIONAL GROUP GENERATION FOR THE BENSONR8 METHOD CANNOT BE COMPLETED
      FOR COMPONENT CHOP.THE FOLLOWING ATOMS WERE NOT MATCHED:
      P 1O 2O 3O 4
                     THE FUNCTIONAL GROUPS GENERATED
          GROUP NUMBERNO. OF OCCUR.   GROUP NUMBERNO. OF OCCUR.
                148          3                  197          3
                137          3                  136         12
                125          3
*   WARNING IN PHYSICAL PROPERTY SYSTEM
      FUNCTIONAL GROUP GENERATION FOR THE LI-MA METHOD CANNOT BE COMPLETED
      FOR COMPONENT CHOP.THE FOLLOWING ATOMS WERE NOT MATCHED:
      P 1
                     THE FUNCTIONAL GROUPS GENERATED
          GROUP NUMBERNO. OF OCCUR.   GROUP NUMBERNO. OF OCCUR.
                157          3                  171         12
                172          6                  203          3
*   WARNING IN PHYSICAL PROPERTY SYSTEM
      FUNCTIONAL GROUP GENERATION FOR THE LEBAS METHOD CANNOT BE COMPLETED
      FOR COMPONENT CHOP.THE FOLLOWING ATOMS WERE NOT MATCHED:
      P 1
                     THE FUNCTIONAL GROUPS GENERATED
          GROUP NUMBERNO. OF OCCUR.   GROUP NUMBERNO. OF OCCUR.
                119          3                  105          3
                101         21                  100         21
*   WARNING IN PHYSICAL PROPERTY SYSTEM
      FUNCTIONAL GROUP GENERATION FOR THE BONDI METHOD CANNOT BE COMPLETED
      FOR COMPONENT CHOP.THE FOLLOWING ATOMS WERE NOT MATCHED:
      P 1
                     THE FUNCTIONAL GROUPS GENERATED
          GROUP NUMBERNO. OF OCCUR.   GROUP NUMBERNO. OF OCCUR.
                122          3                  112          3
                113          3                  111         12
                100          3
*   WARNING IN PHYSICAL PROPERTY SYSTEM
      FUNCTIONAL GROUP GENERATION FOR THE PARACHOR METHOD CANNOT BE COMPLETED
      FOR COMPONENT CHOP.THE FOLLOWING ATOMS WERE NOT MATCHED:
      P 1
                     THE FUNCTIONAL GROUPS GENERATED
          GROUP NUMBERNO. OF OCCUR.   GROUP NUMBERNO. OF OCCUR.
                148          3                  115          3
                106          6                  105         12
                100          3
*   WARNING IN PHYSICAL PROPERTY SYSTEM
      FUNCTIONAL GROUP GENERATION FOR THE REICHENB METHOD CANNOT BE COMPLETED
      FOR COMPONENT CHOP.THE FOLLOWING ATOMS WERE NOT MATCHED:
      P 1
                     THE FUNCTIONAL GROUPS GENERATED
          GROUP NUMBERNO. OF OCCUR.   GROUP NUMBERNO. OF OCCUR.
                100          3                  112         12
                113          6                  118          3
*   WARNING IN PHYSICAL PROPERTY SYSTEM
      FUNCTIONAL GROUP GENERATION FOR THE ORRICK-E METHOD CANNOT BE COMPLETED
      FOR COMPONENT CHOP.THE FOLLOWING ATOMS WERE NOT MATCHED:
      P 1
                     THE FUNCTIONAL GROUPS GENERATED
          GROUP NUMBERNO. OF OCCUR.   GROUP NUMBERNO. OF OCCUR.
                106          3                  107          3
                115          3                  100         21
*   WARNING IN PHYSICAL PROPERTY SYSTEM
      FUNCTIONAL GROUP GENERATION FOR THE RUZICKA METHOD CANNOT BE COMPLETED
      FOR COMPONENT CHOP.THE FOLLOWING ATOMS WERE NOT MATCHED:
      P 1O 2O 3O 4
                     THE FUNCTIONAL GROUPS GENERATED
          GROUP NUMBERNO. OF OCCUR.   GROUP NUMBERNO. OF OCCUR.
                197          3                  137          3
                136         12                  125          3
->Property constant estimation completed
请大家给予帮助,万分感激!!
页: [1]
查看完整版本: 请教:在aspenplus中亚磷酸三邻甲苯酯(C21H21O3P)的物性参数的估算