2411579066 发表于 2023-2-18 21:47:09

甲醇精馏预塔一循环就一直出错,可以怎么处理

The following Unit Operation blocks were
completed with errors:
B14

The following Convergence blocks were
completed with errors:
$OLVER02

The following messages were issued during Input Translation:

*WARNING IN THE 'STREAM' PARAGRAPH WHICH BEGINS ON LINE 117
   STREAM NAME: S29
   COMPONENT MOLE FLOWS OF SUBSTREAM: 'MIXED'
   ARE NORMALIZED TO THE TOTAL MOLE FLOW VALUE.

kbbjq 发表于 2023-2-18 21:47:09

预塔塔顶系统模拟比较复杂,是不是没有采出?

zxckkzxc 发表于 2023-2-18 21:47:09

{:1110_553:}

1146513506@ 发表于 2023-2-18 21:47:09

看看你滴进料输入是不是有问题

jfcl0532 发表于 2023-2-18 21:47:09

存在循环流股,给循环流股赋初值,也就是所谓的撕裂流股!

kkiinngg 发表于 2023-2-18 21:47:09

只有错误信息很难判断原因

ICEMEN521 发表于 2023-2-18 21:47:09

{:1110_553:}

ICEMEN521 发表于 2023-2-18 21:47:09

{:1110_554:}

banknation 发表于 2023-2-18 21:47:09

还是把原文件拿出来,人家才能帮你分析
页: [1]
查看完整版本: 甲醇精馏预塔一循环就一直出错,可以怎么处理