ASPEN打通后查询不到结果 求助!!!!
有没有大佬帮忙解决一下错误 我只是个小小的化工本科生->Processing input specifications ...
* WARNING IN THE "PROP-DATA" PARAGRAPH WHICH BEGINS ON LINE 129
FIRST ID: USRDEF
PARAMETER TB DATA SET 1 FOR COMPONENT 4-PN HAS BEEN
ENTERED MORE THAN ONCE. THE LAST ENTRY WILL BE USED.
* WARNING IN THE "PROP-DATA" PARAGRAPH WHICH BEGINS ON LINE 129
FIRST ID: USRDEF
PARAMETER MW DATA SET 1 FOR COMPONENT 4-PN HAS BEEN
ENTERED MORE THAN ONCE. THE LAST ENTRY WILL BE USED.
* WARNING IN THE "PROP-DATA" PARAGRAPH WHICH BEGINS ON LINE 129
FIRST ID: USRDEF
PARAMETER MW DATA SET 1 FOR COMPONENT HCHO HAS BEEN
ENTERED MORE THAN ONCE. THE LAST ENTRY WILL BE USED.
* WARNING IN PHYSICAL PROPERTY SYSTEM
FUNCTIONAL GROUP GENERATION FOR THE UNIFAC METHOD CANNOT BE COMPLETED
FOR COMPONENT 2M3BN.THE FOLLOWING ATOMS WERE NOT MATCHED:
C 5N 6
THE FUNCTIONAL GROUPS GENERATED
GROUP NUMBERNO. OF OCCUR. GROUP NUMBERNO. OF OCCUR.
1070 1 1015 1
1005 1
* WARNING IN PHYSICAL PROPERTY SYSTEM
FUNCTIONAL GROUP GENERATION FOR THE UNIFAC METHOD CANNOT BE COMPLETED
FOR COMPONENT HCHO.THE FOLLOWING ATOMS WERE NOT MATCHED:
C 1O 2
* WARNING IN PHYSICAL PROPERTY SYSTEM
FUNCTIONAL GROUP GENERATION FOR THE UNIF-LBY METHOD CANNOT BE COMPLETED
FOR COMPONENT 2M3BN.THE FOLLOWING ATOMS WERE NOT MATCHED:
C 5N 6
THE FUNCTIONAL GROUPS GENERATED
GROUP NUMBERNO. OF OCCUR. GROUP NUMBERNO. OF OCCUR.
1070 1 1015 1
1005 1
* WARNING IN PHYSICAL PROPERTY SYSTEM
FUNCTIONAL GROUP GENERATION FOR THE UNIF-LBY METHOD CANNOT BE COMPLETED
FOR COMPONENT HCHO.THE FOLLOWING ATOMS WERE NOT MATCHED:
C 1O 2
* WARNING IN PHYSICAL PROPERTY SYSTEM
FUNCTIONAL GROUP GENERATION FOR THE UNIF-DMD METHOD CANNOT BE COMPLETED
FOR COMPONENT 2M3BN.THE FOLLOWING ATOMS WERE NOT MATCHED:
C 5N 6
THE FUNCTIONAL GROUPS GENERATED
GROUP NUMBERNO. OF OCCUR. GROUP NUMBERNO. OF OCCUR.
1070 1 1015 1
1005 1
* WARNING IN PHYSICAL PROPERTY SYSTEM
FUNCTIONAL GROUP GENERATION FOR THE UNIF-DMD METHOD CANNOT BE COMPLETED
FOR COMPONENT HCHO.THE FOLLOWING ATOMS WERE NOT MATCHED:
C 1O 2
* WARNING IN PHYSICAL PROPERTY SYSTEM
FUNCTIONAL GROUP GENERATION FOR THE UNIF-R4 METHOD CANNOT BE COMPLETED
FOR COMPONENT 2M3BN.THE FOLLOWING ATOMS WERE NOT MATCHED:
C 5N 6
THE FUNCTIONAL GROUPS GENERATED
GROUP NUMBERNO. OF OCCUR. GROUP NUMBERNO. OF OCCUR.
1070 1 1015 1
1005 1
STRUCTURE FOR COMPONENT BD HAS NOT BEEN DEFINED.
PCES CANNOT USE GROUP-CONTRIBUTION METHODS TO ESTIMATE MISSING PROPERTIES
STRUCTURE FOR COMPONENT HCN HAS NOT BEEN DEFINED.
PCES CANNOT USE GROUP-CONTRIBUTION METHODS TO ESTIMATE MISSING PROPERTIES
STRUCTURE FOR COMPONENT H2O HAS NOT BEEN DEFINED.
PCES CANNOT USE GROUP-CONTRIBUTION METHODS TO ESTIMATE MISSING PROPERTIES
STRUCTURE FOR COMPONENT 2-PN HAS NOT BEEN DEFINED.
PCES CANNOT USE GROUP-CONTRIBUTION METHODS TO ESTIMATE MISSING PROPERTIES
STRUCTURE FOR COMPONENT 3-PN HAS NOT BEEN DEFINED.
PCES CANNOT USE GROUP-CONTRIBUTION METHODS TO ESTIMATE MISSING PROPERTIES
STRUCTURE FOR COMPONENT MGN HAS NOT BEEN DEFINED.
PCES CANNOT USE GROUP-CONTRIBUTION METHODS TO ESTIMATE MISSING PROPERTIES
STRUCTURE FOR COMPONENT ADN HAS NOT BEEN DEFINED.
PCES CANNOT USE GROUP-CONTRIBUTION METHODS TO ESTIMATE MISSING PROPERTIES
STRUCTURE FOR COMPONENT 4-C8 HAS NOT BEEN DEFINED.
PCES CANNOT USE GROUP-CONTRIBUTION METHODS TO ESTIMATE MISSING PROPERTIES
STRUCTURE FOR COMPONENT CAT HAS NOT BEEN DEFINED.
PCES CANNOT USE GROUP-CONTRIBUTION METHODS TO ESTIMATE MISSING PROPERTIES
* WARNING IN PHYSICAL PROPERTY SYSTEM
FUNCTIONAL GROUP GENERATION FOR THE BENSON METHOD CANNOT BE COMPLETED
FOR COMPONENT 2M3BN.THE FOLLOWING ATOMS WERE NOT MATCHED:
C 3N 6
THE FUNCTIONAL GROUPS GENERATED
GROUP NUMBERNO. OF OCCUR. GROUP NUMBERNO. OF OCCUR.
133 1 105 1
104 1 100 1
* WARNING IN PHYSICAL PROPERTY SYSTEM
FUNCTIONAL GROUP GENERATION FOR THE REICHENB METHOD CANNOT BE COMPLETED
FOR COMPONENT HCHO.THE FOLLOWING ATOMS WERE NOT MATCHED:
O 2
THE FUNCTIONAL GROUPS GENERATED
GROUP NUMBERNO. OF OCCUR. GROUP NUMBERNO. OF OCCUR.
104 1
* WARNING IN PHYSICAL PROPERTY SYSTEM
FUNCTIONAL GROUP GENERATION FOR THE ORRICK-E METHOD CANNOT BE COMPLETED
FOR COMPONENT HCHO.THE FOLLOWING ATOMS WERE NOT MATCHED:
O 2
THE FUNCTIONAL GROUPS GENERATED
GROUP NUMBERNO. OF OCCUR. GROUP NUMBERNO. OF OCCUR.
100 1
* WARNING IN THE "STREAM" PARAGRAPH WHICH BEGINS ON LINE 373
STREAM NAME: CAT
COMPONENT MASS FRACTIONS ARE NORMALIZED TO UNITY.
**ERROR WHILE CHECKING INPUT SPECIFICATIONS
BLOCK NAME: B2 MODEL NAME: RSTOIC HIERARCHY: B4
REACTION NUMBER "1" DOES NOT SATISFY MASS BALANCE.
THE ABSOLUTE ERROR IS 105.18
CHECK STOICHIOMETRY/MOLECULAR WEIGHTS.
! Errors while processing input specifications
这也叫打通流程,明明是输入有问题 了解了解,谢谢分享 B2的化学反应不守恒。 结构定义不好
页:
[1]