熙熙子 发表于 2023-4-7 19:27:49

ASPEN打通后查询不到结果 求助!!!!

有没有大佬帮忙解决一下错误 我只是个小小的化工本科生
->Processing input specifications ...

*   WARNING IN THE "PROP-DATA" PARAGRAPH WHICH BEGINS ON LINE 129
      FIRST ID: USRDEF
      PARAMETER TB DATA SET 1 FOR COMPONENT 4-PN HAS BEEN
      ENTERED MORE THAN ONCE. THE LAST ENTRY WILL BE USED.

*   WARNING IN THE "PROP-DATA" PARAGRAPH WHICH BEGINS ON LINE 129
      FIRST ID: USRDEF
      PARAMETER MW DATA SET 1 FOR COMPONENT 4-PN HAS BEEN
      ENTERED MORE THAN ONCE. THE LAST ENTRY WILL BE USED.

*   WARNING IN THE "PROP-DATA" PARAGRAPH WHICH BEGINS ON LINE 129
      FIRST ID: USRDEF
      PARAMETER MW DATA SET 1 FOR COMPONENT HCHO HAS BEEN
      ENTERED MORE THAN ONCE. THE LAST ENTRY WILL BE USED.

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      FUNCTIONAL GROUP GENERATION FOR THE UNIFAC METHOD CANNOT BE COMPLETED
      FOR COMPONENT 2M3BN.THE FOLLOWING ATOMS WERE NOT MATCHED:
      C 5N 6

                     THE FUNCTIONAL GROUPS GENERATED
          GROUP NUMBERNO. OF OCCUR.   GROUP NUMBERNO. OF OCCUR.

               1070          1               1015          1
               1005          1

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      FUNCTIONAL GROUP GENERATION FOR THE UNIFAC METHOD CANNOT BE COMPLETED
      FOR COMPONENT HCHO.THE FOLLOWING ATOMS WERE NOT MATCHED:
      C 1O 2

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      FUNCTIONAL GROUP GENERATION FOR THE UNIF-LBY METHOD CANNOT BE COMPLETED
      FOR COMPONENT 2M3BN.THE FOLLOWING ATOMS WERE NOT MATCHED:
      C 5N 6

                     THE FUNCTIONAL GROUPS GENERATED
          GROUP NUMBERNO. OF OCCUR.   GROUP NUMBERNO. OF OCCUR.

               1070          1               1015          1
               1005          1

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      FUNCTIONAL GROUP GENERATION FOR THE UNIF-LBY METHOD CANNOT BE COMPLETED
      FOR COMPONENT HCHO.THE FOLLOWING ATOMS WERE NOT MATCHED:
      C 1O 2

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      FUNCTIONAL GROUP GENERATION FOR THE UNIF-DMD METHOD CANNOT BE COMPLETED
      FOR COMPONENT 2M3BN.THE FOLLOWING ATOMS WERE NOT MATCHED:
      C 5N 6

                     THE FUNCTIONAL GROUPS GENERATED
          GROUP NUMBERNO. OF OCCUR.   GROUP NUMBERNO. OF OCCUR.

               1070          1               1015          1
               1005          1

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      FUNCTIONAL GROUP GENERATION FOR THE UNIF-DMD METHOD CANNOT BE COMPLETED
      FOR COMPONENT HCHO.THE FOLLOWING ATOMS WERE NOT MATCHED:
      C 1O 2

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      FUNCTIONAL GROUP GENERATION FOR THE UNIF-R4 METHOD CANNOT BE COMPLETED
      FOR COMPONENT 2M3BN.THE FOLLOWING ATOMS WERE NOT MATCHED:
      C 5N 6

                     THE FUNCTIONAL GROUPS GENERATED
          GROUP NUMBERNO. OF OCCUR.   GROUP NUMBERNO. OF OCCUR.

               1070          1               1015          1
               1005          1

      STRUCTURE FOR COMPONENT BD HAS NOT BEEN DEFINED.
      PCES CANNOT USE GROUP-CONTRIBUTION METHODS TO ESTIMATE MISSING PROPERTIES

      STRUCTURE FOR COMPONENT HCN HAS NOT BEEN DEFINED.
      PCES CANNOT USE GROUP-CONTRIBUTION METHODS TO ESTIMATE MISSING PROPERTIES

      STRUCTURE FOR COMPONENT H2O HAS NOT BEEN DEFINED.
      PCES CANNOT USE GROUP-CONTRIBUTION METHODS TO ESTIMATE MISSING PROPERTIES

      STRUCTURE FOR COMPONENT 2-PN HAS NOT BEEN DEFINED.
      PCES CANNOT USE GROUP-CONTRIBUTION METHODS TO ESTIMATE MISSING PROPERTIES

      STRUCTURE FOR COMPONENT 3-PN HAS NOT BEEN DEFINED.
      PCES CANNOT USE GROUP-CONTRIBUTION METHODS TO ESTIMATE MISSING PROPERTIES

      STRUCTURE FOR COMPONENT MGN HAS NOT BEEN DEFINED.
      PCES CANNOT USE GROUP-CONTRIBUTION METHODS TO ESTIMATE MISSING PROPERTIES

      STRUCTURE FOR COMPONENT ADN HAS NOT BEEN DEFINED.
      PCES CANNOT USE GROUP-CONTRIBUTION METHODS TO ESTIMATE MISSING PROPERTIES

      STRUCTURE FOR COMPONENT 4-C8 HAS NOT BEEN DEFINED.
      PCES CANNOT USE GROUP-CONTRIBUTION METHODS TO ESTIMATE MISSING PROPERTIES

      STRUCTURE FOR COMPONENT CAT HAS NOT BEEN DEFINED.
      PCES CANNOT USE GROUP-CONTRIBUTION METHODS TO ESTIMATE MISSING PROPERTIES

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      FUNCTIONAL GROUP GENERATION FOR THE BENSON METHOD CANNOT BE COMPLETED
      FOR COMPONENT 2M3BN.THE FOLLOWING ATOMS WERE NOT MATCHED:
      C 3N 6

                     THE FUNCTIONAL GROUPS GENERATED
          GROUP NUMBERNO. OF OCCUR.   GROUP NUMBERNO. OF OCCUR.

                133          1                  105          1
                104          1                  100          1

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      FUNCTIONAL GROUP GENERATION FOR THE REICHENB METHOD CANNOT BE COMPLETED
      FOR COMPONENT HCHO.THE FOLLOWING ATOMS WERE NOT MATCHED:
      O 2

                     THE FUNCTIONAL GROUPS GENERATED
          GROUP NUMBERNO. OF OCCUR.   GROUP NUMBERNO. OF OCCUR.

                104          1

*   WARNING IN PHYSICAL PROPERTY SYSTEM
      FUNCTIONAL GROUP GENERATION FOR THE ORRICK-E METHOD CANNOT BE COMPLETED
      FOR COMPONENT HCHO.THE FOLLOWING ATOMS WERE NOT MATCHED:
      O 2

                     THE FUNCTIONAL GROUPS GENERATED
          GROUP NUMBERNO. OF OCCUR.   GROUP NUMBERNO. OF OCCUR.

                100          1

*   WARNING IN THE "STREAM" PARAGRAPH WHICH BEGINS ON LINE 373
      STREAM NAME: CAT
      COMPONENT MASS FRACTIONS ARE NORMALIZED TO UNITY.

**ERROR WHILE CHECKING INPUT SPECIFICATIONS
      BLOCK NAME: B2    MODEL NAME: RSTOIC   HIERARCHY: B4
      REACTION NUMBER "1" DOES NOT SATISFY MASS BALANCE.
      THE ABSOLUTE ERROR IS   105.18
      CHECK STOICHIOMETRY/MOLECULAR WEIGHTS.

! Errors while processing input specifications


LM010 发表于 2023-4-7 19:27:49

这也叫打通流程,明明是输入有问题

zxz2004 发表于 2023-4-7 19:27:49

了解了解,谢谢分享

imahoupao 发表于 2023-4-7 19:27:49

B2的化学反应不守恒。

lxqlcz135636 发表于 2023-4-7 19:27:49

结构定义不好
页: [1]
查看完整版本: ASPEN打通后查询不到结果 求助!!!!