官能团不能正确产生。用ASpen plus V11估算非库介质产生的问题,大家看看如何解决....
介质CAS: 4170-71-2*WARNING
FUNCTIONAL GROUP GENERATION FOR THE UNIFAC METHOD CANNOT BE COMPLETED
FOR COMPONENT C10H14OS.THE FOLLOWING ATOMS WERE NOT MATCHED:
S 1O 2
THE FUNCTIONAL GROUPS GENERATED
GROUP NUMBERNO. OF OCCUR. GROUP NUMBERNO. OF OCCUR.
1105 5 1100 1
1015 3 1000 1
*WARNING
FUNCTIONAL GROUP GENERATION FOR THE UNIF-LBY METHOD CANNOT BE COMPLETED
FOR COMPONENT C10H14OS.THE FOLLOWING ATOMS WERE NOT MATCHED:
S 1O 2
THE FUNCTIONAL GROUPS GENERATED
GROUP NUMBERNO. OF OCCUR. GROUP NUMBERNO. OF OCCUR.
1105 5 1100 1
1015 3 1000 1
*WARNING
FUNCTIONAL GROUP GENERATION FOR THE UNIF-DMD METHOD CANNOT BE COMPLETED
FOR COMPONENT C10H14OS.THE FOLLOWING ATOMS WERE NOT MATCHED:
S 1O 2
THE FUNCTIONAL GROUPS GENERATED
GROUP NUMBERNO. OF OCCUR. GROUP NUMBERNO. OF OCCUR.
1065 2 1055 1
1015 3 1000 1
*WARNING
FUNCTIONAL GROUP GENERATION FOR THE UNIF-R4 METHOD CANNOT BE COMPLETED
FOR COMPONENT C10H14OS.THE FOLLOWING ATOMS WERE NOT MATCHED:
S 1O 2
THE FUNCTIONAL GROUPS GENERATED
GROUP NUMBERNO. OF OCCUR. GROUP NUMBERNO. OF OCCUR.
1105 5 1100 1
1015 3 1000 1
*WARNING
FUNCTIONAL GROUP GENERATION FOR THE JOBACK METHOD CANNOT BE COMPLETED
FOR COMPONENT C10H14OS.THE FOLLOWING ATOMS WERE NOT MATCHED:
S 1
THE FUNCTIONAL GROUPS GENERATED
GROUP NUMBERNO. OF OCCUR. GROUP NUMBERNO. OF OCCUR.
128 1 100 3
103 1 113 5
114 1
*WARNING
FUNCTIONAL GROUP GENERATION FOR THE LYDERSEN METHOD CANNOT BE COMPLETED
FOR COMPONENT C10H14OS.THE FOLLOWING ATOMS WERE NOT MATCHED:
S 1
THE FUNCTIONAL GROUPS GENERATED
GROUP NUMBERNO. OF OCCUR. GROUP NUMBERNO. OF OCCUR.
130 1 100 3
103 1 114 5
115 1
*WARNING
FUNCTIONAL GROUP GENERATION FOR THE FEDORS METHOD CANNOT BE COMPLETED
FOR COMPONENT C10H14OS.THE FOLLOWING ATOMS WERE NOT MATCHED:
S 1O 2
THE FUNCTIONAL GROUPS GENERATED
GROUP NUMBERNO. OF OCCUR. GROUP NUMBERNO. OF OCCUR.
100 3 103 1
105 5 106 1
146 1
*WARNING
FUNCTIONAL GROUP GENERATION FOR THE AMBROSE METHOD CANNOT BE COMPLETED
FOR COMPONENT C10H14OS.THE FOLLOWING ATOMS WERE NOT MATCHED:
S 1O 2
THE FUNCTIONAL GROUPS GENERATED
GROUP NUMBERNO. OF OCCUR. GROUP NUMBERNO. OF OCCUR.
142 1 134 1
102 1 100 4
*WARNING
FUNCTIONAL GROUP GENERATION FOR THE GANI METHOD CANNOT BE COMPLETED
FOR COMPONENT C10H14OS.THE FOLLOWING ATOMS WERE NOT MATCHED:
S 1O 2
THE FUNCTIONAL GROUPS GENERATED
GROUP NUMBERNO. OF OCCUR. GROUP NUMBERNO. OF OCCUR.
5005 1 1105 5
1100 1 1015 3
1000 1
*WARNING
FUNCTIONAL GROUP GENERATION FOR THE BENSON METHOD CANNOT BE COMPLETED
FOR COMPONENT C10H14OS.THE FOLLOWING ATOMS WERE NOT MATCHED:
S 1O 2
THE FUNCTIONAL GROUPS GENERATED
GROUP NUMBERNO. OF OCCUR. GROUP NUMBERNO. OF OCCUR.
363 1 136 5
100 3 361 1
*WARNING
FUNCTIONAL GROUP GENERATION FOR THE BENSONR8 METHOD CANNOT BE COMPLETED
FOR COMPONENT C10H14OS.THE FOLLOWING ATOMS WERE NOT MATCHED:
S 1O 2
THE FUNCTIONAL GROUPS GENERATED
GROUP NUMBERNO. OF OCCUR. GROUP NUMBERNO. OF OCCUR.
363 1 136 5
100 3 361 1
*WARNING
FUNCTIONAL GROUP GENERATION FOR THE REICHENB METHOD CANNOT BE COMPLETED
FOR COMPONENT C10H14OS.THE FOLLOWING ATOMS WERE NOT MATCHED:
S 1O 2
THE FUNCTIONAL GROUPS GENERATED
GROUP NUMBERNO. OF OCCUR. GROUP NUMBERNO. OF OCCUR.
100 3 103 1
112 5 113 1
*WARNING
FUNCTIONAL GROUP GENERATION FOR THE ORRICK-E METHOD CANNOT BE COMPLETED
FOR COMPONENT C10H14OS.THE FOLLOWING ATOMS WERE NOT MATCHED:
S 1O 2
THE FUNCTIONAL GROUPS GENERATED
GROUP NUMBERNO. OF OCCUR. GROUP NUMBERNO. OF OCCUR.
106 1 101 1
100 10
*WARNING
GROUP CONTRIBUTION VALUE MISSING FOR THE FOLLOWING GROUPS.
SEE NEXT MESSAGE FOR PROPERTY AND METHOD NAMES.
104
恭候高手出现!
介质CAS: 4170-71-2
{:1110_550:} {:1110_550:} 楼主辛苦了 你这个警告是可以忽略的,是因为基团贡献法内没有S=O基团的贡献值 盒子的何 发表于 2023-6-30 13:01
你这个警告是可以忽略的,是因为基团贡献法内没有S=O基团的贡献值
可不可以自己定义这个S=O官能团?还是说没有必要? 我以前找过,JABACK法没有S=O的贡献值,你可以找找其他基团贡献法有没有。