请高手帮我看一下这个提示是什么意思
我在用HYSYS做动态模拟的时候,下面的Trace Window里出现了这样的提示:Heat Exchanger E-100-2 has an excessively low calculated Ft Factor. This is being limited to 0.2 (internal value) since the range of applicability of the correlation has been exceeded.Also may cause dynamics instabilities.If this message persists in dynamics, consider reducing UA.This message will only appear once per session for this Unit Op unless Trace Verbose is turned on.
虽然不认识的单词可以查意思,但是因为我以前不是做化工的,HYSYS也是新手,所以不太懂,能不能请高手帮我解释一下具体是什么意思?出了什么问题?
修正对数温差温度的因子低了,你可以在HYSYS的换热器中把管程数由默认的2改成1.
{:1106_385:}正好解决了我的问题 模式不对不改1 就改模式 把end point 改为另外一个
页:
[1]