guilongli 发表于 2012-3-9 14:58:32

脱硫板式塔的全塔压降一般为多少?

         FRI软件计算天然气脱硫吸收塔全塔压降为9KPa,总共16层塔板,是否合理?
         FRI计算降液管停留时间为5.6s,而化学工程师手册计算结果为31s差距比较大!
造成差距的原因?
      FRI计算output中的专业术语:System limit%
                                                       Jet flood(const Liq)%
                                                       Downcomer flood(const L/V)%
                                                       Press drop mm Hot Liq
                                                      %of jet flood, constant L/V
                                                      %of jet flood, constant Liquid Rate
                                                       system limit capacity factor
                                                       constant L/V Jet flood capacity factor
                                                       constant Liq Jet flood capacity factor
                                                       %ofDC- Flood, constant L/V
                                                       %ofDC- Flood,constant Liquid Rate
                                                       %of Critical Velocity
                                                       计算中对应那部分?






guilongli于2012-3-9 15:01补充以下内容:
还有这个!

guilongli 发表于 2012-3-9 15:51:29

safety factors/error message   对应代表了什么意思?

哇喔 发表于 2012-11-24 23:30:43

楼主给我传一份这个软件嘛

火影魔豆 发表于 2012-11-25 00:02:21

safety factors::安全系数俗称系统因子有体系来决定脱硫的一般选0.75
error message:计算错误
脱硫塔来说一般的 板式塔 要看是浮阀还是筛板系统因子一旦控制 就要看孔动能因子了   这个要根据具体的组分来判断一般来说不会超过7.5%还有就是压降一般很低因为容易发泡

火影魔豆 发表于 2012-11-25 00:24:23

因为引文被河蟹
所以我做成了图片
在附件
自己下载看看
重复的很多,主要:系统因子、喷射液泛率、降液管液泛率

cwyjywqq 发表于 2012-3-9 14:58:32

好好学习,我也在初学

中国好撸 发表于 2012-3-9 14:58:32

我做的脱碳塔也表示jet flood 超过80%,DC backup超过80%,什么意思
页: [1]