本人是新手,计算一个稳定塔,在塔板水力学核算中,得出以下结果,求各位大神帮忙看看结果是不是合适。下面最后出现的警告是什么意思?FF代表什么意思啊?TRAY SIZING RESULTS
TRAYVAPOR LIQUID VLOAD -- DESIGN -- NEXT SMALLER NEXT LARGER NP
M3/S M3/S M3/S DIA, MMFF DIA, MMFF DIA, MMFF
--------- ------------ ------- ---- ------- ---- ------- ---- --
2 0.019 0.00094 0.003 408.3 20.6 381. 34.7 457. 25.9 1
MECHANICAL RESTRICTION ON TRAY 2,FOR FF = 70.0, CALCD. DIA =255.9
3 0.020 0.00098 0.003 416.4 21.3 381. 36.5 457. 27.2 1
MECHANICAL RESTRICTION ON TRAY 3,FOR FF = 70.0, CALCD. DIA =264.0
4 0.020 0.00100 0.003 420.2 21.6 381. 37.4 457. 27.8 1
MECHANICAL RESTRICTION ON TRAY 4,FOR FF = 70.0, CALCD. DIA =267.8
5 0.021 0.00101 0.003 422.1 21.8 381. 37.8 457. 28.1 1
MECHANICAL RESTRICTION ON TRAY 5,FOR FF = 70.0, CALCD. DIA =269.7
6 0.021 0.00102 0.003 423.7 21.9 381. 38.2 457. 28.3 1
MECHANICAL RESTRICTION ON TRAY 6,FOR FF = 70.0, CALCD. DIA =271.3
7 0.021 0.00104 0.003 427.3 22.1 381. 39.1 457. 28.9 1
MECHANICAL RESTRICTION ON TRAY 7,FOR FF = 70.0, CALCD. DIA =274.9
8 0.021 0.00110 0.003 436.3 22.7 381. 41.3 457. 30.5 1
MECHANICAL RESTRICTION ON TRAY 8,FOR FF = 70.0, CALCD. DIA =283.9
** WARNING **Design diameter includes mechanical restriction allowances.
本人在学习中,帮你把帖子顶起来吧{:1106_362:} 学习中,听高手意见 FF为flooding factor就是液泛因子 设计的塔径太小,回收到机械设计的限制,设计时应当注意。{:1106_368:} PROII里最小直径的塔默认为381mm 一般只要比这个直径大 计算就没问题 最好找专业的塔板计算软件算,PROII不准