关于精馏塔设计规定不收敛,请马友帮忙。
用ASPEN PLUS 11.1模拟,建了两个塔K-47501和K-47502,K-47501塔顶CCO要求含萘量小于17%,K-47502塔顶95N要求含萘量大于95%,变量为回流比。怎么调试都不收敛。请马友帮忙。Processing input specifications ...
Flowsheet Analysis :
COMPUTATION ORDER FOR THE FLOWSHEET:
E-47501 E-47502 K-47501 P-47502 K-47502 E-47503 E-47504
E-47514 E-47507
->Calculations begin ...
Block: E-47501Model: HEATER
Block: E-47502Model: HEATER
Block: K-47501Model: RADFRAC
Convergence iterations:
OL ML IL Err/Tol
1 1 4 25.183
2 7 23 1.5039
3 5 15 1.4117
4 5 10 1.3663
5 5 12 1.2973
6 5 11 1.2189
7 5 11 1.1438
8 2 4 0.58201
**ERROR
DESIGN SPEC IS NOT SATISFIED BECAUSE ONE OR MORE MANIPULATED
VARIABLE IS AT ITS BOUND.
Block: P-47502Model: PUMP
Block: K-47502Model: RADFRAC
Convergence iterations:
OL ML IL Err/Tol
1 1 4 40.788
2 7 30 15.894
3 8 22 11.313
4 7 21 5.1139
5 7 17 4.0299
6 2 5 0.28653
**ERROR
DESIGN SPEC IS NOT SATISFIED BECAUSE ONE OR MORE MANIPULATED
VARIABLE IS AT ITS BOUND.
Block: E-47503Model: HEATER
Block: E-47504Model: HEATER
Block: E-47514Model: HEATER
Block: E-47507Model: HEATER
->Simulation calculations completed ...
你的设计规定有问题 应该怎么规定? 把回流比的设计规定范围做下修改,你再试试。 你最哈先做一个 随着你的操纵变量在你设定的范围内的最大值和最小值,看看你这个设定值在不在这个范围之内,估计是不在 将回流比设计规定改成D/F设计规定,OK了。 chrisqsnn 发表于 2013-2-3 00:10 static/image/common/back.gif
将回流比设计规定改成D/F设计规定,OK了。
是不是之前知道答案呀。。。。
看了一会文件找不出原因,怎样将回流比设计规定改成D/F设计规定?
胜源毅 发表于 2013-2-3 02:53 static/image/common/back.gif
是不是之前知道答案呀。。。。
看了一会文件找不出原因,怎样将回流比设计规定改成D/F设计规定?
没看文件。
我猜测他可能block设置改成了d/f,然后又改设计规定为d/f
设计变量 达到了边界。aspen使用的算法不计算边界值。把范围更改一下。
页:
[1]