liyongrui 发表于 2013-2-20 15:28:40

热力学模型参数关联时,BIP 设定。help 文档

热力学模型参数关联时,BIP 设定。help 文档
You can load BIP data into your user database via the neutral file.The format of each BIP line is:

BIP      type      sec-ID      BIP-A,

The BIP type must be one of the following:
       NRTL
       PR (Peng-Robinson)
       SRK (Soave-Redlich-Kwong)
       UNIQUAC
       WILSON
       BWRS
       ESD
       SAFT
Valid names are listed in the BIPNAMES.SF file in the system directory.
The BIP sec-ID is the secondary ID for this BIP data. Associated with each set of BIP values are, of course, two components; the primary component and the secondary component. The BIP keyword must be included somewhere between a pair of STRC and ENDC keywords. The STRC and ENDC keywords define a group of lines pertaining to the same component and it is assumed that this component is the primary component. The BIP sec-ID is the secondary ID associated with this BIP data and is the CHEMCAD ID number for the secondary component.You can specify any secondary ID so long as it is numerically less than the primary ID. For example, the following BIP line specifies values for WILSON BIPs between a user-added component and water (CHEMCAD ID for water is 62).

BIP      WILSON      62      -52.605      620.63

If the current group of lines in your neutral file pertains to component 8001 and you include the following line in this group, it would be discarded because the secondary ID is greater than the primary ID:

BIP      WILSON      8005      -52.605      620.63               

The order in which you specify the BIP parameters is important. You must specify at least one BIP parameter. The maximum number of parameters depends on which BIP type you are specifying.
The BIPNAMES.SF file in the system directory includes the maximum number of parameters that can be specified for each BIP type. The order in which you specify BIP parameters is also important. The following list indicates the correct ordering for each BIP type:

BIP      NRTL                secID      Bij, Bji, alphaIJ, Aij, Aji                        
BIP      PR                secID      Bij                                       
BIP      SRK                secID      Bij                                       
BIP      UNIQUAC      secID      Aij, Aji, Uij, Uji                              
BIP      WILSON      secID      Aij, Aji                                       
BIP      BWRS                secID      Kij                                       
BIP      ESD                secID      Kij, KTij, KaLin, dHLin, KaBin, dHBin      
BIP      SAFT                secID      Kij, KTij, KaLin, dHLin, KaBin, dHBin      

化工枪人 发表于 2013-2-20 15:28:40

这么强悍,扫噶!{:1106_362:}{:1106_366:}
页: [1]