旋风king 发表于 2013-6-5 12:00:59

用aspen模拟气相循环是不收敛怎么办呢??求解决办法和原因

Loop $OLVER01 Method: WEGSTEIN   Iteration   30
*   WARNING
      CONVERGENCE BLOCK $OLVER01 NOT CONVERGED IN 30 ITERATIONS
   8 vars not converged, Max Err/Tol-0.52296E+03
>> Loop $OLVER01 exceeded maximum iterations.
   Block: VALVE    Model: VALVE
   Block: DSTWU    Model: DSTWU
**ERROR
      BLOCK FLASH2 IS NOT IN MASS BALANCE:
      MASS INLET FLOW = 0.13131742E+02, MASS OUTLET FLOW = 0.13191316E+02
      RELATIVE DIFFERENCE = 0.45366362E-02
      MAY BE DUE TO A TEAR STREAM OR A STREAM FLOW MAY HAVE
      BEEN CHANGED BY A FORTRAN, TRANSFER, OR BALANCE BLOCK
      AFTER THE BLOCK HAD BEEN EXECUTED.
**ERROR
      Convergence block $OLVER01 did not converge
      normally in the final pass

这个错误是什么意思呢??求解决问题办法???真心感谢

wh8768 发表于 2013-6-5 12:00:59

旋风king 发表于 2013-6-8 15:01
aspen里面有试差法???怎么用,,在哪里呢

不是aspen里有,你把循环物流拆下来、只作为出料(假设是1),混合器那加一股进料(假设是2),,,调整2使其与1很接近,就可以认为是循环的了

ken6666 发表于 2013-6-5 12:00:59

把 tears 內的物流刪掉就能解決了

尕元子 发表于 2013-6-5 12:00:59

把迭代次数变为100试试啊,就是没有收敛的意思,可以通过改迭代次数和收敛方法,使其收敛的

萃取 发表于 2013-6-5 12:00:59

果断MARK,前十有我必火!

wh8768 发表于 2013-6-5 12:00:59

你那个回流导致流程不收敛,实在不行就用试差法,一点不费劲

旋风king 发表于 2013-6-5 12:00:59

wh8768 发表于 2013-6-8 11:34
你那个回流导致流程不收敛,实在不行就用试差法,一点不费劲

aspen里面有试差法???怎么用,,在哪里呢

xmy101 发表于 2013-6-5 12:00:59

wh8768 发表于 2013-6-9 08:34
不是aspen里有,你把循环物流拆下来、只作为出料(假设是1),混合器那加一股进料(假设是2),,,调整2 ...

就是这样做的,比撕裂流方便多了

嘉嘉318 发表于 2013-6-5 12:00:59

那怎么拆呢,就是说,循环物料不能加到新鲜物料的混合器里是么?

xiaoling0916 发表于 2013-6-5 12:00:59

嘉嘉318 发表于 2014-5-20 15:30
那怎么拆呢,就是说,循环物料不能加到新鲜物料的混合器里是么?

请问楼主问题解决了吗?我今天模拟也遇到同样的问题~

闻雅的刘瑞 发表于 2013-6-5 12:00:59

http://meng.horse//mobcent//app/data/phiz/default/03.png

lovedalikai 发表于 2013-6-5 12:00:59

尕元子 发表于 2013-6-5 23:07
把迭代次数变为100试试啊,就是没有收敛的意思,可以通过改迭代次数和收敛方法,使其收敛的

今天碰到类似的问题,按照你说的,一下子就解决了。眼前一亮啊。{:1106_362:}

yingxiongmolu 发表于 2013-6-5 12:00:59

物料不守恒,对MIXER模块做物料衡算可谓解决的方法之一。

IWANS 发表于 2013-6-5 12:00:59

经常遇到不收敛问题,学习学习经验
页: [1]
查看完整版本: 用aspen模拟气相循环是不收敛怎么办呢??求解决办法和原因