zg_zhiguang 发表于 2014-4-16 15:16:21

aspen用radfrac模块模拟吸收时出现如下现象,请高手指点

aspen用radfrac模块模拟吸收时出现如下现象,请高手指点

Processing input specifications ...

      INFORMProcessing input specifications ...
      INFORMATION
      BINARY PARAMETERS PRKIJ (DATA SET 1) FOR MODEL ESPRSTD
      ARE RETRIEVED FROM SDF TABLE.TABLE NAME = ESPRSTD

Flowsheet Analysis :

COMPUTATION ORDER FOR THE FLOWSHEET:
B1

->Calculations begin ...


    Block: B1       Model: RADFRAC

       Convergence iterations:
         OL   ML   IL   Err/Tol
          1    1    3      215.03
          2    1   10      686.78
          3    1   10      759.04
          4    1   10      844.55
          5    1   10      946.31
          6    1   10      1068.6
          7    1   10      1167.9
          8    1    5      218.22
          9    1    3      33.992
         10    1    5      4.0895
         11    1    6      1.8688
         12    1    4   0.81057
*** SEVERE ERROR
      THE FOLLOWING STAGES DRIED UP (VAPOR OR LIQUID FLOW APPROACHES 0):
      1    2
      A LIMIT OF0.10000E-04 * SUM OF FEEDS WAS IMPOSED ON THE FLOW RATES
      OR A LIMIT OF0.10000E-04 WAS IMPOSED ON THE STAGE V/L OR L/V RATIO.


->Simulation calculations completed ...


zg_zhiguang 发表于 2014-4-16 15:16:21

补充一下,甲醇吸收二氧化碳,
出现干板现象,是哪里的问题

hkkotw 发表于 2014-4-16 15:16:21

改变板数呢