lugan 发表于 2014-5-19 12:22:26

产物流与进料换热后始终不收敛怎么解决?

如题所示,不知道如何解决。Processing input specifications ...
Flowsheet Analysis :

Block $OLVER01 (Method: WEGSTEIN) has been defined to converge
         streams: 8

COMPUTATION ORDER FOR THE FLOWSHEET:
B1
$OLVER01 B2 B3 B4
(RETURN $OLVER01)

->Calculations begin ...


   Block: B1       Model: MIXER

> Beginning Convergence Loop $OLVER01 Method: WEGSTEIN

   Block: B2       Model: HEATX
*   WARNING
      AT LEAST ONE FEED HAS ZERO FLOW
      BLOCK BYPASSED


   Block: B3       Model: HEATER

   Block: B4       Model: RYIELD
*   WARNING
      THE FOLLOWING ELEMENTS ARE NOT IN ATOM BALANCE:
      H   O   C


> Loop $OLVER01 Method: WEGSTEIN   Iteration    1
18 vars not converged, Max Err/Tol   0.10000E+07

   Block: B2       Model: HEATX

   Block: B3       Model: HEATER

   Block: B4       Model: RYIELD
*   WARNING
      THE FOLLOWING ELEMENTS ARE NOT IN ATOM BALANCE:
      H   O   C


> Loop $OLVER01 Method: WEGSTEIN   Iteration    2
# Converged            Max Err/Tol   0.00000E+00

->Generating block results ...

    Block: B2       Model: HEATX

->Simulation calculations completed ...


aaasssaa 发表于 2014-5-19 12:22:26

同求学习一下

1040534752 发表于 2014-5-19 12:22:26

帮你看个错误,得耗5两马蹄,真厉害!

1040534752 发表于 2014-5-19 12:22:26

这已经收敛了,你用的产率反应器,可以把原子守恒这一项勾掉。另一项付个初值就行了。

lugan 发表于 2014-5-19 12:22:26

非常感谢感谢帮忙解决问题

lugan 发表于 2014-5-19 12:22:26

1040534752 发表于 2014-5-19 15:48
帮你看个错误,得耗5两马蹄,真厉害!

你好,这个不知道怎么设置,如果你知道的话能告诉我怎么设置吗?

1040534752 发表于 2014-5-19 12:22:26

现在好像改成5马蹄了,以前是2马蹄。
页: [1]
查看完整版本: 产物流与进料换热后始终不收敛怎么解决?