精馏塔简洁计算时遇到的问题,运行有错误,但是找不到在哪里。已附加bkp文件
这是运行错误时出现的提示* WARNING WHILE CHECKING INPUT SPECIFICATIONS
INCONSISTENT FREE-WATER DETECTED FOR STREAM "1"
GLOBAL FREE-WATER: NO
BLOCK "B1" FREE-WATER: YES
Flowsheet Analysis :
COMPUTATION ORDER FOR THE FLOWSHEET:
B1
->Calculations begin ...
Block: B1 Model: DSTWU
*** SEVERE ERROR
FLASH CALCULATIONS FAILED TO CONVERGE IN10ITERATIONS. BUBBLE POINT
CALCULATION HAS DRIVEN THE TEMPERATURE DOWN TO THE LOWER LIMIT OF
14.9837 DEGREE K.BUBBLE POINT TEMPERATURE MAY NOT EXIST AT THE
SPECIFIED PRESSURE.BUBBLE POINT FLASH OF FEED TO CALCULATE FEED QUALITY
FAILED.FEED VAPOR FRACTION USED FOR QUALITY.
*** SEVERE ERROR
K-VALUE OF LIGHT KEY COMPONENT IN DISTILLATE IS 0.18446-164
AT A DISTILLATE TEMPERATURE OF 20.940.
UNABLE TO CALCULATE MINIMUM NUMBER OF STAGES.CALCULATIONS BYPASSED.
**ERROR
BLOCK B1 IS NOT IN MASS BALANCE:
MASS INLET FLOW = 0.87524255E+01, MASS OUTLET FLOW = 0.76283630E+01
RELATIVE DIFFERENCE = 0.14735305E+00
我也遇到相同的问题,同求。。 进料那么多H2,还全凝器?把氢气闪蒸出去再精馏吧 1040534752 发表于 2014-6-28 22:26
进料那么多H2,还全凝器?把氢气闪蒸出去再精馏吧
请问模拟前出现 * WARNING WHILE CHECKING INPUT SPECIFICATIONS
INCONSISTENT FREE-WATER DETECTED FOR STREAM "XS-1"
FROM BLOCK: "XS-1"FREE-WATER: NO
TO BLOCK: "XQ-1"FREE-WATER: YES
但是模拟后又没有错误和警告是什么问题, yx244373732 发表于 2014-6-28 22:43
请问模拟前出现 * WARNING WHILE CHECKING INPUT SPECIFICATIONS
INCONSISTENT FREE-WATER DE ...
请问这个问题已经解决了吗,我卡在这儿了,求指导呀!! wky 发表于 2014-6-29 16:16
请问这个问题已经解决了吗,我卡在这儿了,求指导呀!!
解决了,我做的流程是闪蒸器哪里的设置有问题,调了一下就好了。 我也遇到同样的问题 没有气体就没事 有气体就跟你 出现一样的问题 你怎么解决的 终于找到答案了,还是这里最靠谱,谢谢,问题已解决^_^ uranuszz 发表于 2014-8-11 11:27
终于找到答案了,还是这里最靠谱,谢谢,问题已解决^_^
请问是怎么解决的呀?能不能指点一下呢?
874083392 发表于 2015-5-11 18:11
请问是怎么解决的呀?能不能指点一下呢?
这个做的很久了,记得是在冷凝器哪里,要设定气相比例。在这种条件下,没办法做到全凝的。 yx244373732 发表于 2014-7-8 09:37
**** 作者被禁止或删除 内容自动屏蔽 ****
具体怎么调的可以说一下嘛?
uranuszz 发表于 2015-5-13 09:32
这个做的很久了,记得是在冷凝器哪里,要设定气相比例。在这种条件下,没办法做到全凝的。
解决了,真的感谢 uranuszz 发表于 2015-5-13 09:32
这个做的很久了,记得是在冷凝器哪里,要设定气相比例。在这种条件下,没办法做到全凝的。
太有帮助了,感谢