yx244373732 发表于 2014-6-28 21:56:45

计算前出错了,但是计算完又没有错是什么问题!

Run reinitialized 21:50:30 Sat Jun 28, 2014>>

->Processing input specifications ...
      INFORMATION
      BINARY PARAMETERS RKSKIJ (DATA SET 1) FOR MODEL ESRKSTD
      ARE RETRIEVED FROM SDF TABLE.TABLE NAME = ESRKSTD
*   WARNING WHILE CHECKING INPUT SPECIFICATIONS
      INCONSISTENT FREE-WATER DETECTED FOR STREAM "XS-2"
      FROM BLOCK: "XQ-1"FREE-WATER: YES
      TO BLOCK: "XP-1"FREE-WATER: NO
*   WARNING WHILE CHECKING INPUT SPECIFICATIONS
      INCONSISTENT FREE-WATER DETECTED FOR STREAM "XS-1"
      FROM BLOCK: "XS-1"FREE-WATER: NO
      TO BLOCK: "XQ-1"FREE-WATER: YES
->Simulation calculations completed ...

***No Warnings were issued during Input Translation ***

***No Errors or Warnings were issued during Simulation ***


全场工艺流程草图.bkp(590.49KB)
全场工艺流程草图.bkp(590.49KB)
全场工艺流程草图.bkp(590.49KB)

doding 发表于 2014-6-28 21:56:45

XS1 若设定 free water 就应该没问题
其实XS1 和 XQ1 可以合并,前面加一个减压阀
H2OUT 和 FEIQI 也就合一了

wuqitao9999 发表于 2014-6-28 21:56:45

其实XS1 和 XQ1 可以合并,前面加一个减压阀

yx244373732 发表于 2014-6-28 21:56:45

doding 发表于 2014-6-28 23:31
XS1 若设定 free water 就应该没问题
其实XS1 和 XQ1 可以合并,前面加一个减压阀
H2OUT 和 FEIQI 也就合 ...

恩,谢谢,问题解决了

yx244373732 于 2014-07-08 09:39:54 补充以下内容:
谢谢,问题解决了。
页: [1]