计算前出错了,但是计算完又没有错是什么问题!
Run reinitialized 21:50:30 Sat Jun 28, 2014>>->Processing input specifications ...
INFORMATION
BINARY PARAMETERS RKSKIJ (DATA SET 1) FOR MODEL ESRKSTD
ARE RETRIEVED FROM SDF TABLE.TABLE NAME = ESRKSTD
* WARNING WHILE CHECKING INPUT SPECIFICATIONS
INCONSISTENT FREE-WATER DETECTED FOR STREAM "XS-2"
FROM BLOCK: "XQ-1"FREE-WATER: YES
TO BLOCK: "XP-1"FREE-WATER: NO
* WARNING WHILE CHECKING INPUT SPECIFICATIONS
INCONSISTENT FREE-WATER DETECTED FOR STREAM "XS-1"
FROM BLOCK: "XS-1"FREE-WATER: NO
TO BLOCK: "XQ-1"FREE-WATER: YES
->Simulation calculations completed ...
***No Warnings were issued during Input Translation ***
***No Errors or Warnings were issued during Simulation ***
全场工艺流程草图.bkp(590.49KB)
全场工艺流程草图.bkp(590.49KB)
全场工艺流程草图.bkp(590.49KB) XS1 若设定 free water 就应该没问题
其实XS1 和 XQ1 可以合并,前面加一个减压阀
H2OUT 和 FEIQI 也就合一了
其实XS1 和 XQ1 可以合并,前面加一个减压阀
doding 发表于 2014-6-28 23:31
XS1 若设定 free water 就应该没问题
其实XS1 和 XQ1 可以合并,前面加一个减压阀
H2OUT 和 FEIQI 也就合 ...
恩,谢谢,问题解决了
yx244373732 于 2014-07-08 09:39:54 补充以下内容:
谢谢,问题解决了。