aspen模拟调试时遇到的不收敛问题和泵的问题
> Loop $OLVER01 Method: WEGSTEIN Iteration 30* WARNING
CONVERGENCE BLOCK $OLVER01 NOT CONVERGED IN 30 ITERATIONS
3 vars not converged, Max Err/Tol-0.61910E+03
**ERROR
Convergence block $OLVER01 did not converge
normally in the final pass
->Generating block results ...
Block: ABS Model: HEATER
**ERROR WHILE GENERATING RESULTS FOR UNIT OPERATIONS BLOCK: "ABS" (MODEL:
"HEATER")
T-LOOP NOT CONVERGED IN49ITERATIONS.
Block: COND Model: HEATER
Block: PUMP Model: PUMP
INFORMATION WHILE GENERATING RESULTS FOR UNIT OPERATIONS BLOCK: "PUMP"
(MODEL: "PUMP")
NET POSITIVE SUCTION HEAD IS LESS THAN ZERO
* WARNING WHILE GENERATING RESULTS FOR UNIT OPERATIONS BLOCK: "PUMP"
(MODEL: "PUMP")
VAPOR EXISTS IN THE OUTLET STREAM, AND THE VALUE (0.64075)
IS GREATER THAN THAT IN THE INLET STREAM (0.0000).
THE RESULTS MAY BE UNRELIABLE.
->Simulation calculations completed ...
***Warning(s) were issued during Input Translation ***
***Check the Run Status Results for more Information ***
***Summary of Simulation Errors***
Physical
Property System Simulation
Terminal Errors 0 0 0
Severe Errors 0 0 0
Errors 0 0 2
Warnings 0 0 2
->Generating results ...
bkp文件见附件!!急求啊
收敛问题一直搞不懂{:1106_361:} 枫叶的思念 发表于 2015-3-21 14:06
收敛问题一直搞不懂
一样样的,哎,快无语了
页: