ASPEN模拟换热器经常出问题是咋回事?
Beginning Convergence Loop $OLVER01 Method: WEGSTEINBlock: E1501 Model: HEATX
* WARNING
AT LEAST ONE FEED HAS ZERO FLOW
BLOCK BYPASSED
Block: E1503 Model: HEATX
* WARNING
AT LEAST ONE FEED HAS ZERO FLOW
BLOCK BYPASSED
Block: R1501 Model: RSTOIC
Block: E1502 Model: HEATX
> Loop $OLVER01 Method: WEGSTEIN Iteration 1
12 vars not converged, Max Err/Tol 0.10000E+07
Block: E1501 Model: HEATX
**ERROR
INVALID HOT STREAM TEMPERATURE SPECIFICATION
T-SPEC =6.6005000D+02 IS MORE THAN THIN =5.8044222D+02
大家帮我分析下咋回事
都零流量了,还不检查一下 是否是冷热物流弄反了? 应该是冷或者热物流流量太小了吧