a604342882 发表于 2019-7-18 14:39:26

aspen dynamics常减压塔稳态转动态时出错 救救孩子

在完成常压塔稳态模拟后,输入塔规格后转动态后出现错误。The specified pressure drops in the column are smaller than the liquid head on the stages listed below. Please adjust the pressure profile on the Pressure sheet of the Setup form. A typical total pressure drop across a stage is twice the pressure drop due to liquid head. Alternatively, modify the weir heights or column diameter on these stages. If you are modelling a packed column, select the Simple Packing option on the Hydraulics sheet of the Dynamics form. If you are using tray-rating or packing-rating, ensure your input parameters are consistent.

P_dropL = Pressure drop due to liquid head on stage (Bar).
P_drop= Total pressure drop on stage (Bar).

Column                        Stage      P_dropL (Bar)                        P_drop (Bar)
Main column          40         8.498200257260e-003          6.976750000000e-003
Main column          41         8.307378669079e-003          6.976740000000e-003
Main column          42         8.275587413854e-003          6.976750000000e-003
Main column          43         8.235240351578e-003          6.976740000000e-003
Stripper "S-1"          1         5.571108114083e-003          1.428600000000e-004
Stripper "S-1"          2         5.549680105266e-003          1.428600000000e-004
Stripper "S-1"          3         5.534057151594e-003          1.428500000000e-004
Stripper "S-1"          4         5.521777639571e-003          1.428600000000e-004
Stripper "S-1"          5         5.511223830525e-003          1.428600000002e-004
Stripper "S-1"          6         5.501520219496e-003          1.428499999998e-004
Stripper "S-1"          7         5.491800618281e-003          1.428600000002e-004
Stripper "S-2"          1         7.541680777681e-003          1.200000000001e-004
Stripper "S-2"          2         7.494013156024e-003          1.199999999999e-004
Stripper "S-2"          3         7.454344375785e-003          1.200000000001e-004
Stripper "S-2"          4         7.412202078064e-003          1.199999999999e-004
Stripper "S-2"          5         7.355420473100e-003          1.200000000001e-004
Stripper "S-3"          1         4.846295250924e-003          1.200000000001e-004
Stripper "S-3"          2         4.850959277406e-003          1.199999999999e-004
Stripper "S-3"          3         4.852078262643e-003          1.200000000001e-004
Stripper "S-3"          4         4.852250816209e-003          1.199999999999e-004
Stripper "S-3"          5         4.850267392464e-003          1.200000000001e-004

FATAL ERROR: Please correct the errors above before continuing
Aborting procedure D:\Program Files\Aspen Plus V8.4\GUI\\Ast\PETROFRAC.TBL
求大佬帮忙看看,塔的压力已经调到最大了,再大稳态就不收敛了,我实在是不知道该调什么了,拜托大家了!



页: [1]