sonic0519 发表于 2013-3-8 09:45:01

物料不平衡的能否EO input设置该怎么设置


我目前做了个n多循环的工艺,做了n遍下面几个模块物料不守恒,是否可在EO input里面设置,但是该怎么设置呢 ?我从来没用过,有高人指点吗!

**ERROR
      BLOCK B3 IS NOT IN MASS BALANCE:
      MASS INLET FLOW = 0.12492302E-02, MASS OUTLET FLOW = 0.12500000E-02
      RELATIVE DIFFERENCE = 0.61625617E-03
      A STREAM FLOW MAY HAVE BEEN CHANGED BY A FORTRAN, TRANSFER,
      OR BALANCE BLOCK AFTER THE BLOCK HAD BEEN EXECUTED.

**ERROR
      BLOCK B4 IS NOT IN MASS BALANCE:
      MASS INLET FLOW = 0.41572882E-03, MASS OUTLET FLOW = 0.41587663E-03
      RELATIVE DIFFERENCE = 0.35555643E-03
      A STREAM FLOW MAY HAVE BEEN CHANGED BY A FORTRAN, TRANSFER,
      OR BALANCE BLOCK AFTER THE BLOCK HAD BEEN EXECUTED.

**ERROR
      BLOCK B0 IS NOT IN MASS BALANCE:
      MASS INLET FLOW = 0.27507141E-02, MASS OUTLET FLOW = 0.27503362E-02
      RELATIVE DIFFERENCE = 0.13742534E-03
      A STREAM FLOW MAY HAVE BEEN CHANGED BY A FORTRAN, TRANSFER,
      OR BALANCE BLOCK AFTER THE BLOCK HAD BEEN EXECUTED.

sonic0519 发表于 2013-3-8 09:45:01

隐身猪 发表于 2013-3-8 13:26 static/image/common/back.gif
在tear中把tolerance改小点试试。

这个我已经改过了。。

箬ю葙倁 发表于 2013-3-8 09:45:01

楼主这个问题解决没?。。。求指教呀。。。EO input这该怎么设置呢

1592203609 发表于 2013-3-8 09:45:01

同求指导!求

donggua 发表于 2013-3-8 09:45:01

EO INPUT在哪个地方啊
页: [1]
查看完整版本: 物料不平衡的能否EO input设置该怎么设置