*   WARNING
      AT LEAST ONE FEED HAS ZERO FLOW
      BLOCK BYPASSED


   Block: E302     Model: HEATER
  *   WARNING
      ZERO FEED TO THE BLOCK.  BLOCK BYPASSED


   Block: V301     Model: FLASH2
  *   WARNING
      ZERO FEED TO THE BLOCK.  BLOCK BYPASSED


   Block: M201B    Model: FSPLIT
  *   WARNING
      ZERO FEED TO THE BLOCK. BLOCK BYPASSED


   Block: R301     Model: RSTOIC

> Loop $OLVER01 Method: DIRECT-SUBST Iteration    1
  Converging tear streams: 11        6
  11 vars not converged, Max Err/Tol   0.10000E+07

   Block: M201A    Model: MIXER

   Block: C201B    Model: COMPR

   Block: B5       Model: HEATX

   Block: E302     Model: HEATER

   Block: V301     Model: FLASH2

   Block: M201B    Model: FSPLIT

   Block: R301     Model: RSTOIC

> Loop $OLVER01 Method: DIRECT-SUBST Iteration    2
  Converging tear streams: 11        6
  11 vars not converged, Max Err/Tol   0.10000E+07

   Block: M201A    Model: MIXER

   Block: C201B    Model: COMPR

   Block: B5       Model: HEATX
  **  ERROR
      TEMPERATURE CROSSOVER DETECTED
      RE-CALCULATING WITH MINIMUM APPROACH TEMP. SPEC
问题一:请问一下出现*   WARNING      ZERO FEED TO THE BLOCK.  BLOCK BYPASSED但是最终流程收敛了,这种情况对最终结果有什么影响?
问题二: 出现错误RE-CALCULATING WITH MINIMUM APPROACH TEMP. SPEC,这种情况对最终结果有什么影响?
问题三:以上问题该怎么处理?具体情况请看附件!告诉我怎么处理这类问题,特别是问题一的,经常遇到但不知道怎么处理好!请各位指点一下!




                               
登录/注册后可看大图
该贴已经同步到 SuperDJ的微博
一般没对aspen判定的撕裂流股赋初值时在第一次计算时会有提示,如果流程最后显示收敛,计算结果可用(即显示为蓝色提示),则流程收敛成功,对最终结果无任何影响。
请问楼主这个问题解决了没有,是怎么解决的,我也遇到了这一样的问题我该怎么解决???



                                                                                        望回复,谢谢!
我也遇到了同样的问题,如果解决了帮帮忙吧,特别感谢
问题一:请问一下出现*   WARNING      ZERO FEED TO THE BLOCK.  BLOCK BYPASSED但是最终流程收敛了,这种情况对最终结果有什么影响?

输入物流给定合理初值就好了
不收敛,换热温度交叉了,可以规定换热后冷物流的温度小于热物流进口或者热物流的出口温度小于冷物流进口,上面说的只是对完全逆流换热,对于多程换热,可以尝试减小换热DUTY